Purdue University
Dynamic analysis of dynamic cone penetration test for subgrade compaction assessment
Abstract
dc:description.abstract<p>In practice, soil compaction quality assessment relies on the determination of the in-place compacted dry unit weight, which is then compared with the maximum dry unit weight obtained from a laboratory compaction test. Most DOTs typically require that the in-place dry unit weight for compacted soil be over 95% of the laboratory maximum dry unit weight obtained from Standard Proctor compaction test results. Nuclear gauges may be used to determine the in-place dry unit weight, however, they are potentially hazardous and require safety precautions. Other tests, such as the Dynamic Cone Penetration Test (DCPT), can be used for soil compaction quality assessment.</p>
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy (PhD)
- Level thesis:degree_level
- Dissertation
- Discipline thesis:degree_discipline
- Civil Engineering
- Year
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kim, Hobi
- Contributors dc:contributor
-
- Monica Prezzi
- Rodrigo Salgado
- Ayhan Irfanoglu
- Arun Prakash
Subjects
dc:subject × 5Identifiers
dc:identifier.*- Repository record dc:identifier
- https://docs.lib.purdue.edu/open_access_dissertations/1053
- OAI identifier oai:identifier
- oai:docs.lib.purdue.edu:open_access_dissertations-2269