Back to results

Case Western Reserve University School of Graduate Studies

A WIRELESS ELECTRICAL STIMULATION SYSTEMFOR WOUND HEALING THERAPYWITH BIPHASIC HIGH-VOLTAGE PULSED CURRENT OUTPUT

Abstract

dc:description

<p>In this research, two wearable surface stimulation systems have been developed for use in wound electrotherapy. These self-contained, battery-powered bandages have been demonstrated in-vivo using both a rat chronic wound model and a pig infected wound model and provide a new means to investigate the physiological mechanisms of wound healing.</p><p>The first stimulation bandage was designed for use with a rat wound model and consists of a stimulator PCB module and plastic electrode bandage. The PCB is constructed from discrete COTS components and is powered by a small button cell battery providing at least seven days of continuous use. This voltage-mode device generates stimulation pulses that are 10 - 90 V in amplitude, 10 - 200 µs in width, and 12 – 25 Hz in frequency. Stimulation was typically applied to wounds for 10 minutes every hour for one week, and then the device and wound dressings were replaced. </p><p>An ASIC has been developed using the OnSemi 0.7-µm I2T100 process and iscapable of operation up to 100 V. A high-gain, current-mode boost converter addresses challenges associated with efficient generation of the large amplitude compliance voltage (up to 90 V) from a small battery with limited output current capability. A biphasic current mode stimulator was demonstrated with ±21-mA output range, 0.33-mA resolution, and a voltage headroom requirement of 3.5 V at full scale output.</p><p>The second stimulation bandage uses this ASIC and was designed for use on larger wounds, up to 6 cm in diameter. A rechargeable lithium polymer battery allows a single stimulator module to be used for an entire 28-day study. The disposable electrode bandage portion of the device is easily replaced in-situ by the clinician. Continuous monitoring of the delivered stimulation current while the device is in place on an animal is achieved using a microcontroller with a built-in Bluetooth Low Energy radio. Performance information from up to six devices is recorded to a wireless base station located outside the animal pen and may also be remotely accessed by research personnel. </p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
EECS - Electrical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Howe, Daniel Steven
Contributors dc:contributor
  • Garverick, Steven

Subjects

dc:subject × 11

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:etd.ohiolink.edu:case1365179992

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Howe, Daniel Steven. A WIRELESS ELECTRICAL STIMULATION SYSTEMFOR WOUND HEALING THERAPYWITH BIPHASIC HIGH-VOLTAGE PULSED CURRENT OUTPUT. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2013. http://rave.ohiolink.edu/etdc/view?acc_num=case1365179992