University of Missouri--Rolla
System level ESD failure mechanisms, analysis and test method
Abstract
dc:description.abstract"This dissertation, composed of four papers, discusses three topics related to system level electrostatic discharge. In the first paper, the discharge current and the transient fields of an ESD generator in the contact mode are numerically simulated using the FDTD method...The second and the third papers derived a reference ESD event for human-metal ESD from measured discharges...In the fourth paper, a three dimensional ESD scanning system which has been developed to record the ESD susceptibility map for printed circuit board is presented and the mechanisms that the ESD event couples into the digital devices is studied"--Abstract, page iv.
Degree
thesis:*- Name thesis:degree_name
- Ph. D. in Electrical Engineering
- Grantor
- University of Missouri--Rolla
- Year dc:date.available
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Wang, Kai
Subjects
dc:subject × 1Identifiers
dc:identifier.*- Repository record dc:identifier
- https://scholarsmine.mst.edu/doctoral_dissertations/1657
- OAI identifier oai:identifier
- oai:scholarsmine.mst.edu:doctoral_dissertations-2659