Back to results

Massachusetts Institute of Technology

Biological dosimetry of neutron beams for neutron capture therapies

Abstract

dc:description.abstract

Boron neutron capture therapies using the 10B(n,a)7Li reaction have been proposed as treatments for glioblastoma multiforme, metastatic melanoma, rheumatoid arthritis, and other debilitating conditions. This thesis presents the first combined biological and physical dosimetry interbeam comparison data of three neutron beams used in boron neutron capture therapies: the Massachusetts Institute of Technology (MIT) and Brookhaven National Laboratory epithermal neutron beam facilities previously used in Phase I/II human clinical trials of boron neutron capture therapy (BNCT), and the boron neutron capture synovectomy (BNCS) facility at MIT. The biological dosimetry methodology developed included in vitro irradiation of rodent cells at various depths in a water-filled phantom that simulated healthy tissue. These experiments evaluated the biological effectiveness of the neutron and photon components since no boron was present. Cell survival at a given dose was dependent upon the depth in the phantom as a result of moderation and attenuation of the beam components by overlying water. Results were compared with 250 kVp X-ray irradiations to determine relative biological effectiveness (RBE) values of the beams; neutron RBE values were calculated from the beam RBE values.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Nuclear Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • White, Susan Marie, 1973-
Advisor dc:contributor.advisor
  • Jacquelyn C. Yanch.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/8679
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/8679

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

White, Susan Marie, 1973-. Biological dosimetry of neutron beams for neutron capture therapies. Massachusetts Institute of Technology, 2001. http://hdl.handle.net/1721.1/8679