{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/8679"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/8679","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Biological dosimetry of neutron beams for neutron capture therapies","abstract":"Boron neutron capture therapies using the 10B(n,a)7Li reaction have been proposed as treatments for glioblastoma multiforme, metastatic melanoma, rheumatoid arthritis, and other debilitating conditions. This thesis presents the first combined biological and physical dosimetry interbeam comparison data of three neutron beams used in boron neutron capture therapies: the Massachusetts Institute of Technology (MIT) and Brookhaven National Laboratory epithermal neutron beam facilities previously used in Phase I/II human clinical trials of boron neutron capture therapy (BNCT), and the boron neutron capture synovectomy (BNCS) facility at MIT. The biological dosimetry methodology developed included in vitro irradiation of rodent cells at various depths in a water-filled phantom that simulated healthy tissue. These experiments evaluated the biological effectiveness of the neutron and photon components since no boron was present. Cell survival at a given dose was dependent upon the depth in the phantom as a result of moderation and attenuation of the beam components by overlying water. Results were compared with 250 kVp X-ray irradiations to determine relative biological effectiveness (RBE) values of the beams; neutron RBE values were calculated from the beam RBE values.","abstract_html":"Boron neutron capture therapies using the 10B(n,a)7Li reaction have been proposed as treatments for glioblastoma multiforme, metastatic melanoma, rheumatoid arthritis, and other debilitating conditions. This thesis presents the first combined biological and physical dosimetry interbeam comparison data of three neutron beams used in boron neutron capture therapies: the Massachusetts Institute of Technology (MIT) and Brookhaven National Laboratory epithermal neutron beam facilities previously used in Phase I/II human clinical trials of boron neutron capture therapy (BNCT), and the boron neutron capture synovectomy (BNCS) facility at MIT. The biological dosimetry methodology developed included in vitro irradiation of rodent cells at various depths in a water-filled phantom that simulated healthy tissue. These experiments evaluated the biological effectiveness of the neutron and photon components since no boron was present. Cell survival at a given dose was dependent upon the depth in the phantom as a result of moderation and attenuation of the beam components by overlying water. Results were compared with 250 kVp X-ray irradiations to determine relative biological effectiveness (RBE) values of the beams; neutron RBE values were calculated from the beam RBE values.","abstract_has_math":false,"creators":["White, Susan Marie, 1973-"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Nuclear Engineering","school":null,"contributors":[],"advisors":["Jacquelyn C. Yanch."],"committee_chairs":[],"committee_members":[],"year":2001,"date_issued":"2001","date_published":"2001","updated_at":"2026-07-22T22:21:11Z","subjects":["Nuclear Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/8679","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jacquelyn C. Yanch."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Nuclear Engineering","Massachusetts Institute of Technology. Department of Nuclear Science and Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Nuclear Engineering."]},{"key":"dc:creator","label":"Author","values":["White, Susan Marie, 1973-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-08-23T22:16:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-08-23T22:16:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2001"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nuclear Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/8679"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 2001.","Includes bibliographical references (leaves 161-167)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Boron neutron capture therapies using the 10B(n,a)7Li reaction have been proposed as treatments for glioblastoma multiforme, metastatic melanoma, rheumatoid arthritis, and other debilitating conditions. This thesis presents the first combined biological and physical dosimetry interbeam comparison data of three neutron beams used in boron neutron capture therapies: the Massachusetts Institute of Technology (MIT) and Brookhaven National Laboratory epithermal neutron beam facilities previously used in Phase I/II human clinical trials of boron neutron capture therapy (BNCT), and the boron neutron capture synovectomy (BNCS) facility at MIT. The biological dosimetry methodology developed included in vitro irradiation of rodent cells at various depths in a water-filled phantom that simulated healthy tissue. These experiments evaluated the biological effectiveness of the neutron and photon components since no boron was present. Cell survival at a given dose was dependent upon the depth in the phantom as a result of moderation and attenuation of the beam components by overlying water. Results were compared with 250 kVp X-ray irradiations to determine relative biological effectiveness (RBE) values of the beams; neutron RBE values were calculated from the beam RBE values."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Biological dosimetry of neutron beams for neutron capture therapies"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jacquelyn C. Yanch."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Nuclear Engineering","Massachusetts Institute of Technology. Department of Nuclear Science and Engineering"],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Nuclear Engineering."],"dc:creator":["White, Susan Marie, 1973-"],"dc:date.accessioned":["2005-08-23T22:16:14Z"],"dc:date.available":["2005-08-23T22:16:14Z"],"dc:date.issued":["2001"],"dc:description":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 2001.","Includes bibliographical references (leaves 161-167)."],"dc:description.abstract":["Boron neutron capture therapies using the 10B(n,a)7Li reaction have been proposed as treatments for glioblastoma multiforme, metastatic melanoma, rheumatoid arthritis, and other debilitating conditions. This thesis presents the first combined biological and physical dosimetry interbeam comparison data of three neutron beams used in boron neutron capture therapies: the Massachusetts Institute of Technology (MIT) and Brookhaven National Laboratory epithermal neutron beam facilities previously used in Phase I/II human clinical trials of boron neutron capture therapy (BNCT), and the boron neutron capture synovectomy (BNCS) facility at MIT. The biological dosimetry methodology developed included in vitro irradiation of rodent cells at various depths in a water-filled phantom that simulated healthy tissue. These experiments evaluated the biological effectiveness of the neutron and photon components since no boron was present. Cell survival at a given dose was dependent upon the depth in the phantom as a result of moderation and attenuation of the beam components by overlying water. Results were compared with 250 kVp X-ray irradiations to determine relative biological effectiveness (RBE) values of the beams; neutron RBE values were calculated from the beam RBE values."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/8679"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Nuclear Engineering."],"dc:title":["Biological dosimetry of neutron beams for neutron capture therapies"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:11Z"}