Back to results

Massachusetts Institute of Technology

Evaluating the performance of natural ventilation in buildings through simulation and on-site monitoring

Abstract

dc:description.abstract

Natural ventilation in buildings is capable of reducing energy consumption while maintaining a comfortable indoor at the same time. It is important that natural ventilation is taken into consideration in the early design stage, probably through simulation program. However, existing simulation programs are limited because of their model assumption, simulation efficiency and user friendliness. In this document a simulation program, CoolVent, is presented. It implements a multi-node, thermal and energy coupled model to simulate natural ventilation in buildings. The program is validated to be effective and efficient in simulation. Combined with the DOE building database, CoolVent evaluates the performance of different ventilation modes in different types of building and weather conditions. The second half of this thesis includes a detailed on-site monitoring study of a naturally ventilated building in Boston. It details the post-occupancy system characteristics. The monitoring results have also been compared with CoolVent. The simulation results are verified by comparing with the monitored ones. The program is then used to evaluate the potential of improved operation.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Architecture.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cheng, Haofan
Advisor dc:contributor.advisor
  • Leon R. Glicksman.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/81745
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/81745

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Cheng, Haofan. Evaluating the performance of natural ventilation in buildings through simulation and on-site monitoring. Massachusetts Institute of Technology, 2013. http://hdl.handle.net/1721.1/81745