{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/81745"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/81745","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Evaluating the performance of natural ventilation in buildings through simulation and on-site monitoring","abstract":"Natural ventilation in buildings is capable of reducing energy consumption while maintaining a comfortable indoor at the same time. It is important that natural ventilation is taken into consideration in the early design stage, probably through simulation program. However, existing simulation programs are limited because of their model assumption, simulation efficiency and user friendliness. In this document a simulation program, CoolVent, is presented. It implements a multi-node, thermal and energy coupled model to simulate natural ventilation in buildings. The program is validated to be effective and efficient in simulation. Combined with the DOE building database, CoolVent evaluates the performance of different ventilation modes in different types of building and weather conditions. The second half of this thesis includes a detailed on-site monitoring study of a naturally ventilated building in Boston. It details the post-occupancy system characteristics. The monitoring results have also been compared with CoolVent. The simulation results are verified by comparing with the monitored ones. The program is then used to evaluate the potential of improved operation.","abstract_html":"Natural ventilation in buildings is capable of reducing energy consumption while maintaining a comfortable indoor at the same time. It is important that natural ventilation is taken into consideration in the early design stage, probably through simulation program. However, existing simulation programs are limited because of their model assumption, simulation efficiency and user friendliness. In this document a simulation program, CoolVent, is presented. It implements a multi-node, thermal and energy coupled model to simulate natural ventilation in buildings. The program is validated to be effective and efficient in simulation. Combined with the DOE building database, CoolVent evaluates the performance of different ventilation modes in different types of building and weather conditions. The second half of this thesis includes a detailed on-site monitoring study of a naturally ventilated building in Boston. It details the post-occupancy system characteristics. The monitoring results have also been compared with CoolVent. The simulation results are verified by comparing with the monitored ones. The program is then used to evaluate the potential of improved operation.","abstract_has_math":false,"creators":["Cheng, Haofan"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Architecture.","school":null,"contributors":[],"advisors":["Leon R. Glicksman."],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-07-22T22:21:18Z","subjects":["Architecture."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/81745","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Leon R. Glicksman."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Architecture."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Architecture."]},{"key":"dc:creator","label":"Author","values":["Cheng, Haofan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-10-24T18:12:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-10-24T18:12:09Z"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Architecture."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/81745"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M. in Building Technology)--Massachusetts Institute of Technology, Dept. of Architecture, 2013.","This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Vita. Cataloged from student-submitted PDF version of thesis.","Includes bibliographical references (p. 120-121)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Natural ventilation in buildings is capable of reducing energy consumption while maintaining a comfortable indoor at the same time. It is important that natural ventilation is taken into consideration in the early design stage, probably through simulation program. However, existing simulation programs are limited because of their model assumption, simulation efficiency and user friendliness. In this document a simulation program, CoolVent, is presented. It implements a multi-node, thermal and energy coupled model to simulate natural ventilation in buildings. The program is validated to be effective and efficient in simulation. Combined with the DOE building database, CoolVent evaluates the performance of different ventilation modes in different types of building and weather conditions. The second half of this thesis includes a detailed on-site monitoring study of a naturally ventilated building in Boston. It details the post-occupancy system characteristics. The monitoring results have also been compared with CoolVent. The simulation results are verified by comparing with the monitored ones. The program is then used to evaluate the potential of improved operation."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M.in Building Technology"]},{"key":"dc:title","label":"Title","values":["Evaluating the performance of natural ventilation in buildings through simulation and on-site monitoring"]}]}],"canonical_facts":{"dc:contributor.advisor":["Leon R. Glicksman."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Architecture."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Architecture."],"dc:creator":["Cheng, Haofan"],"dc:date.accessioned":["2013-10-24T18:12:09Z"],"dc:date.available":["2013-10-24T18:12:09Z"],"dc:date.issued":["2013"],"dc:description":["Thesis (S.M. in Building Technology)--Massachusetts Institute of Technology, Dept. of Architecture, 2013.","This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Vita. Cataloged from student-submitted PDF version of thesis.","Includes bibliographical references (p. 120-121)."],"dc:description.abstract":["Natural ventilation in buildings is capable of reducing energy consumption while maintaining a comfortable indoor at the same time. It is important that natural ventilation is taken into consideration in the early design stage, probably through simulation program. However, existing simulation programs are limited because of their model assumption, simulation efficiency and user friendliness. In this document a simulation program, CoolVent, is presented. It implements a multi-node, thermal and energy coupled model to simulate natural ventilation in buildings. The program is validated to be effective and efficient in simulation. Combined with the DOE building database, CoolVent evaluates the performance of different ventilation modes in different types of building and weather conditions. The second half of this thesis includes a detailed on-site monitoring study of a naturally ventilated building in Boston. It details the post-occupancy system characteristics. The monitoring results have also been compared with CoolVent. The simulation results are verified by comparing with the monitored ones. The program is then used to evaluate the potential of improved operation."],"dc:description.degree":["S.M.in Building Technology"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/81745"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Architecture."],"dc:title":["Evaluating the performance of natural ventilation in buildings through simulation and on-site monitoring"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:18Z"}