Back to results

Massachusetts Institute of Technology

Capabilities and limitations of Phase Contrast Imaging techniques with X-rays and neutrons

Abstract

dc:description.abstract

Phase Contrast Imaging (PCI) was studied with the goal of understanding its relevance and its requirements. Current literature does not provide insight on the effect of a relaxation in coherence requirements on the PCI capabilities of an imaging system. This problem is all the more important since coherent X-ray and Neutron sources are mostly unavailable. We develop a model for PCI contribution to imaging for partially incoherent systems, and develop a methodology to identify a minimum and an optimum coherence length 4min and opt. We propose a figure-of-merit KPcI that quantifies the PCI capabilities of an imaging system. Our calculations show that X-ray PCI systems based on free space propagation using microfocus X-ray tubes have little PCI capabilities. We develop a model to explain the edge enhancement observed with those systems; our results suggest that scatter reduction is the process responsible for the observed edge enhancement. We performed experiments that show good agreement with the model. Coded Source Imaging (CSI) is proposed as a tool to produce highly coherent sources. The general theory of CSI is developed. We propose two possible systems: Fluorescent Coded Sources (FCS) and the AEB Encoded X-ray tube.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Damato, Antonio Leonardo
Advisor dc:contributor.advisor
  • Richard C. Lanza.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/53263
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/53263

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Damato, Antonio Leonardo. Capabilities and limitations of Phase Contrast Imaging techniques with X-rays and neutrons. Massachusetts Institute of Technology, 2009. http://hdl.handle.net/1721.1/53263