{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/53263"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/53263","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Capabilities and limitations of Phase Contrast Imaging techniques with X-rays and neutrons","abstract":"Phase Contrast Imaging (PCI) was studied with the goal of understanding its relevance and its requirements. Current literature does not provide insight on the effect of a relaxation in coherence requirements on the PCI capabilities of an imaging system. This problem is all the more important since coherent X-ray and Neutron sources are mostly unavailable. We develop a model for PCI contribution to imaging for partially incoherent systems, and develop a methodology to identify a minimum and an optimum coherence length 4min and opt. We propose a figure-of-merit KPcI that quantifies the PCI capabilities of an imaging system. Our calculations show that X-ray PCI systems based on free space propagation using microfocus X-ray tubes have little PCI capabilities. We develop a model to explain the edge enhancement observed with those systems; our results suggest that scatter reduction is the process responsible for the observed edge enhancement. We performed experiments that show good agreement with the model. Coded Source Imaging (CSI) is proposed as a tool to produce highly coherent sources. The general theory of CSI is developed. We propose two possible systems: Fluorescent Coded Sources (FCS) and the AEB Encoded X-ray tube.","abstract_html":"Phase Contrast Imaging (PCI) was studied with the goal of understanding its relevance and its requirements. Current literature does not provide insight on the effect of a relaxation in coherence requirements on the PCI capabilities of an imaging system. This problem is all the more important since coherent X-ray and Neutron sources are mostly unavailable. We develop a model for PCI contribution to imaging for partially incoherent systems, and develop a methodology to identify a minimum and an optimum coherence length 4min and opt. We propose a figure-of-merit KPcI that quantifies the PCI capabilities of an imaging system. Our calculations show that X-ray PCI systems based on free space propagation using microfocus X-ray tubes have little PCI capabilities. We develop a model to explain the edge enhancement observed with those systems; our results suggest that scatter reduction is the process responsible for the observed edge enhancement. We performed experiments that show good agreement with the model. Coded Source Imaging (CSI) is proposed as a tool to produce highly coherent sources. The general theory of CSI is developed. We propose two possible systems: Fluorescent Coded Sources (FCS) and the AEB Encoded X-ray tube.","abstract_has_math":false,"creators":["Damato, Antonio Leonardo"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.","school":null,"contributors":[],"advisors":["Richard C. Lanza."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-07-22T22:21:18Z","subjects":["Nuclear Science and Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/53263","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Richard C. Lanza."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering."]},{"key":"dc:creator","label":"Author","values":["Damato, Antonio Leonardo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-03-25T15:22:53Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-03-25T15:22:53Z"]},{"key":"dc:date.issued","label":"Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nuclear Science and Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/53263"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, February 2009.","Cataloged from PDF version of thesis.","Includes bibliographical references."]},{"key":"dc:description.abstract","label":"Abstract","values":["Phase Contrast Imaging (PCI) was studied with the goal of understanding its relevance and its requirements. Current literature does not provide insight on the effect of a relaxation in coherence requirements on the PCI capabilities of an imaging system. This problem is all the more important since coherent X-ray and Neutron sources are mostly unavailable. We develop a model for PCI contribution to imaging for partially incoherent systems, and develop a methodology to identify a minimum and an optimum coherence length 4min and opt. We propose a figure-of-merit KPcI that quantifies the PCI capabilities of an imaging system. Our calculations show that X-ray PCI systems based on free space propagation using microfocus X-ray tubes have little PCI capabilities. We develop a model to explain the edge enhancement observed with those systems; our results suggest that scatter reduction is the process responsible for the observed edge enhancement. We performed experiments that show good agreement with the model. Coded Source Imaging (CSI) is proposed as a tool to produce highly coherent sources. The general theory of CSI is developed. We propose two possible systems: Fluorescent Coded Sources (FCS) and the AEB Encoded X-ray tube."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Capabilities and limitations of Phase Contrast Imaging techniques with X-rays and neutrons"]}]}],"canonical_facts":{"dc:contributor.advisor":["Richard C. Lanza."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering."],"dc:creator":["Damato, Antonio Leonardo"],"dc:date.accessioned":["2010-03-25T15:22:53Z"],"dc:date.available":["2010-03-25T15:22:53Z"],"dc:date.issued":["2009"],"dc:description":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, February 2009.","Cataloged from PDF version of thesis.","Includes bibliographical references."],"dc:description.abstract":["Phase Contrast Imaging (PCI) was studied with the goal of understanding its relevance and its requirements. Current literature does not provide insight on the effect of a relaxation in coherence requirements on the PCI capabilities of an imaging system. This problem is all the more important since coherent X-ray and Neutron sources are mostly unavailable. We develop a model for PCI contribution to imaging for partially incoherent systems, and develop a methodology to identify a minimum and an optimum coherence length 4min and opt. We propose a figure-of-merit KPcI that quantifies the PCI capabilities of an imaging system. Our calculations show that X-ray PCI systems based on free space propagation using microfocus X-ray tubes have little PCI capabilities. We develop a model to explain the edge enhancement observed with those systems; our results suggest that scatter reduction is the process responsible for the observed edge enhancement. We performed experiments that show good agreement with the model. Coded Source Imaging (CSI) is proposed as a tool to produce highly coherent sources. The general theory of CSI is developed. We propose two possible systems: Fluorescent Coded Sources (FCS) and the AEB Encoded X-ray tube."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/53263"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Nuclear Science and Engineering."],"dc:title":["Capabilities and limitations of Phase Contrast Imaging techniques with X-rays and neutrons"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:18Z"}