Back to results

Massachusetts Institute of Technology

Design of an endoscopic biopsy needle with flexural members

Abstract

dc:description.abstract

As a minimally invasive means of extracting a tissue sample from a patient, current endoscopic biopsy needles generally do not preserve tissue histology and often require multiple attempts to obtain a tissue sample. This paper presents an endoscopic biopsy needle with internal flexures that enable tissue to enter the hollow needle and then be severed from surrounding tissue when the needle is withdrawn. Using force-deflection and sample weight data from 10x scaled prototypes, variations of a flexural design captured 1.1 grams of a tissue phantom on average, as compared to wedge-type designs that averaged of 0.7-0.8 grams. Peak entrance forces for the flexure design were lower than for both wedge and extended wedge designs, and resistance forces were higher upon needle extraction. A low-angle 15-degree feature produced lower entrance resistance and larger exit resistance compared with 30 degree, 45 degree, and 60 degree features, which is desirable when retaining tissue. Manufacturing of a 1x scale prototypes, using a grinding and laser cutting process, suggested that flexural features could be produced in current endoscopic biopsy needles, but changes to the beveled cutting tip would first have to be made before flexural elements could be tested on actual liver samples.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Figueredo, Stacy L. (Stacy Lee), 1981-
Advisor dc:contributor.advisor
  • Alexander H. Slocum.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/38273
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/38273

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Figueredo, Stacy L. (Stacy Lee), 1981-. Design of an endoscopic biopsy needle with flexural members. Massachusetts Institute of Technology, 2006. http://hdl.handle.net/1721.1/38273