Back to results

Massachusetts Institute of Technology

Real time PCR measurement by fluorescence anisotropy

Abstract

dc:description.abstract

Real-time polymerase chain reaction (PCR) is the gold-standard for quantitation in both mutation and gene expression analyses. Already this technique has found valuable clinical application in disease diagnosis and progression evaluation. As the number of known gene-disease correlations continues to rise, there will be increased demand for higher throughput and decreased cost for these analyses. Present real-time PCR measurement is based upon the fluorescent intensity of either intercalating dyes or oligonucleotide probes. Intercalating dye methods suffer from a lack of binding specificity, while probe methods are expensive and require increased assay optimization. In this thesis, a new method is presented for monitoring real-time PCR that utilizes the fluorescent anisotropy (FA) of labeled primers. FA, when measured at constant temperature, is indicative of the molecular mass to which the fluorophore is attached. Specificity is improved with the FA method over the use of intercalating dyes since the selective binding of primers is required for signal change. Assay complexity and cost are reduced compared to fluorogenic probe methods since the probes are eliminated. The design of a prototype instrument, which successfully implements this new method, is presented. Instrument and assay performance are compared to intercalating dye assays run in commercially available instrumentation. Theoretical limits on performance are also presented and compared to experimental results. Excellent repeatability and linearity are observed with respect to these benchmarks. This new method, having both high specificity and low optimization complexity, is expected to be particularly applicable to the demanding robustness requirements of nano-scale PCR.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Crane, Bryan Lee, 1976-
Advisor dc:contributor.advisor
  • Ian W. Hunter.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/30347
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/30347

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Crane, Bryan Lee, 1976-. Real time PCR measurement by fluorescence anisotropy. Massachusetts Institute of Technology, 2005. http://hdl.handle.net/1721.1/30347