Back to results

Massachusetts Institute of Technology

Resolution improvement in optical microscopy by use of multi-beam interferometric illumination

Abstract

dc:description.abstract

In conventional optical microscopy, the numerical aperture (NA) of the objective lens intrinsically links the resolution, depth of field (DOF), working distance (WD) and field of view (FOV). In a diffraction-limited system, changing the NA to improve resolution is not possible without degrading the other optical performances. This linkage, which represents an important limitation in conventional microscopy, has now been broken. In the new method, a target is illuminated by a sequence of finely textured light patterns generated by interference of multiple coherent beams that converge in a cone. The corresponding sequence of brightness values, measured by a single photodetector (e.g., a single pixel of a CCD), encodes the target's sub-pixel contrast pattern. Fourier domain components at spatial frequencies contained in the probing illumination patterns can be recovered from the pixel brightness sequence by solving a set of over-determined linear equations. For a given wavelength, the resolution of the reconstructed image is primarily determined by the NA of the cone of beams, rather than the NA of the microscope objective. A low NA objective, with large DOF, long WD, and large FOV, can be used without compromising resolution. A cone of 31 coherent beams with NA of 0.98 is produced from a single source beam ([lambda] = 488 nm) using an acousto-optic deflector (AOD) and an all-reflective beam delivery system. The target is placed where the beams overlap. Fluoresced light from the target is collected with a 0.2 NA objective for 930 different interference patterns. Brightness sequences are decoded to reconstruct an image with resolution comparable to what would be obtained

Degree

thesis:*
Department dc:contributor.department
Harvard University--MIT Division of Health Sciences and Technology.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ryu, Jekwan, 1970-
Advisor dc:contributor.advisor
  • Dennis M. Freeman.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/29959
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/29959

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Ryu, Jekwan, 1970-. Resolution improvement in optical microscopy by use of multi-beam interferometric illumination. Massachusetts Institute of Technology, 2003. http://hdl.handle.net/1721.1/29959