Back to results

Massachusetts Institute of Technology

Development and Evaluation of a Potentially Wearable Device for Circulating Cell Monitoring

Abstract

dc:description.abstract

Monitoring circulating cells is crucial for assessing cancer metastasis and evaluating the efficacy of chimeric antigen receptor (CAR) T-cell therapies. Traditional blood-draw methods face challenges such as discontinuous monitoring and potential cell degradation, leading to inaccurate estimations. In vivo flow cytometry (IVFC), which measures real-time cellular response to laser illumination such as fluorescence, presents a viable alternative. However, its application in humans has been limited by the bulky design of existing devices and configurations unsuitable for larger organisms. This thesis introduces a novel, wearable fluorescence IVFC device tailored for human use, featuring a compact laser diode and silicon photomultiplier (SiPM) to enhance portability and functionality. The device includes a specialized optical system similar to a fluorescent microscope, which optimizes the signal- to-noise ratio by maximizing cellular fluorescence and minimizing background interference. Experimental determination of the limit of detection (LOD) for the SiPM and device establishes their detection capabilities and operational stability. Theoretical evaluations confirm that while the device can detect individual fluorescent cells in vitro, its current configuration does not support this sensitivity in vivo. The thesis also proposes strategies to improve the device’s sensitivity, aiming for reliable in vivo detection of single fluorescent cells.

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
Program in Media Arts and Sciences (Massachusetts Institute of Technology)
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jang, Kyuho
Advisor dc:contributor.advisor
  • Sarkar, Deblina

Rights

dc:rights
Statement dc:rights
  • In Copyright - Educational Use Permitted
  • Copyright retained by author(s)

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/159370
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/159370

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Jang, Kyuho. Development and Evaluation of a Potentially Wearable Device for Circulating Cell Monitoring. Massachusetts Institute of Technology, 2024. https://hdl.handle.net/1721.1/159370