Back to results

Massachusetts Institute of Technology

Sequence-phase optimal (SPO) [d̳e̳l̳t̳a̳]B₀ field control for lipid suppression and homogeneity for brain magnetic resonance spectroscopic imaging

Abstract

dc:description.abstract

This work develops sequence-phase optimal (SPO) [delta]B₀ shimming methods to reduce lipid contamination and improve brain metabolite spectra in proton spectroscopic imaging. A rapidly reconfigurable 32-channel, local-multi-coil-shim-array is used to enhance lipid suppression and narrow metabolite linewidth in magnetic resonance spectroscopic imaging (MRSI) of the brain. The array is optimally reconfigured dynamically during each MRSI repetition period, first during the lipid-suppression phase, by widening the spectral gap between spatially separate lipid and metabolite regions, and then to narrow metabolite linewidth during readout, by brain-only [delta]B₀ homogenization. This sequence-phase-optimal (SPO) shimming approach is demonstrated on four volunteer subjects using a commercial 3T MRI outfitted with a 32-channel integrated RF receive and local multi-coil shim array. This proposed sequence-phase-optimal shimming significantly improves brain-metabolite MRSI in vivo, as measured by lipid suppression, brain metabolite chemical shift, and line widths. The time required to compute patient specific SPO shims negligibly impacted scan time. Sequence-phase-optimal shimming reduced lipid energy in the brain volume across four subjects by 88%, improved NAA FWHM by 23%, and dramatically reduced lipid ringing artifacts in quantified NAA and Glutamate metabolites, without increasing scan time or SAR.

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Arango, Nicolas(Nicolas S.)
Advisor dc:contributor.advisor
  • Jacob White.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/128411
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/128411

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Arango, Nicolas(Nicolas S.). Sequence-phase optimal (SPO) [d̳e̳l̳t̳a̳]B₀ field control for lipid suppression and homogeneity for brain magnetic resonance spectroscopic imaging. Massachusetts Institute of Technology, 2020. https://hdl.handle.net/1721.1/128411