{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/128411"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/128411","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Sequence-phase optimal (SPO) [d̳e̳l̳t̳a̳]B₀ field control for lipid suppression and homogeneity for brain magnetic resonance spectroscopic imaging","abstract":"This work develops sequence-phase optimal (SPO) [delta]B₀ shimming methods to reduce lipid contamination and improve brain metabolite spectra in proton spectroscopic imaging. A rapidly reconfigurable 32-channel, local-multi-coil-shim-array is used to enhance lipid suppression and narrow metabolite linewidth in magnetic resonance spectroscopic imaging (MRSI) of the brain. The array is optimally reconfigured dynamically during each MRSI repetition period, first during the lipid-suppression phase, by widening the spectral gap between spatially separate lipid and metabolite regions, and then to narrow metabolite linewidth during readout, by brain-only [delta]B₀ homogenization. This sequence-phase-optimal (SPO) shimming approach is demonstrated on four volunteer subjects using a commercial 3T MRI outfitted with a 32-channel integrated RF receive and local multi-coil shim array. This proposed sequence-phase-optimal shimming significantly improves brain-metabolite MRSI in vivo, as measured by lipid suppression, brain metabolite chemical shift, and line widths. The time required to compute patient specific SPO shims negligibly impacted scan time. Sequence-phase-optimal shimming reduced lipid energy in the brain volume across four subjects by 88%, improved NAA FWHM by 23%, and dramatically reduced lipid ringing artifacts in quantified NAA and Glutamate metabolites, without increasing scan time or SAR.","abstract_html":"This work develops sequence-phase optimal (SPO) [delta]B₀ shimming methods to reduce lipid contamination and improve brain metabolite spectra in proton spectroscopic imaging. A rapidly reconfigurable 32-channel, local-multi-coil-shim-array is used to enhance lipid suppression and narrow metabolite linewidth in magnetic resonance spectroscopic imaging (MRSI) of the brain. The array is optimally reconfigured dynamically during each MRSI repetition period, first during the lipid-suppression phase, by widening the spectral gap between spatially separate lipid and metabolite regions, and then to narrow metabolite linewidth during readout, by brain-only [delta]B₀ homogenization. This sequence-phase-optimal (SPO) shimming approach is demonstrated on four volunteer subjects using a commercial 3T MRI outfitted with a 32-channel integrated RF receive and local multi-coil shim array. This proposed sequence-phase-optimal shimming significantly improves brain-metabolite MRSI in vivo, as measured by lipid suppression, brain metabolite chemical shift, and line widths. The time required to compute patient specific SPO shims negligibly impacted scan time. Sequence-phase-optimal shimming reduced lipid energy in the brain volume across four subjects by 88%, improved NAA FWHM by 23%, and dramatically reduced lipid ringing artifacts in quantified NAA and Glutamate metabolites, without increasing scan time or SAR.","abstract_has_math":false,"creators":["Arango, Nicolas(Nicolas S.)"],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science","school":null,"contributors":[],"advisors":["Jacob White."],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-07-22T22:22:22Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/128411","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jacob White."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science","EECS"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Arango, Nicolas(Nicolas S.)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-11-06T21:08:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-11-06T21:08:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/128411"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, February, 2020","Cataloged from PDF version of thesis. [d̳e̳l̳t̳a̳] in title on title page appears as upper case Greek letter.","Includes bibliographical references (pages 33-35)."]},{"key":"dc:description.abstract","label":"Abstract","values":["This work develops sequence-phase optimal (SPO) [delta]B₀ shimming methods to reduce lipid contamination and improve brain metabolite spectra in proton spectroscopic imaging. A rapidly reconfigurable 32-channel, local-multi-coil-shim-array is used to enhance lipid suppression and narrow metabolite linewidth in magnetic resonance spectroscopic imaging (MRSI) of the brain. The array is optimally reconfigured dynamically during each MRSI repetition period, first during the lipid-suppression phase, by widening the spectral gap between spatially separate lipid and metabolite regions, and then to narrow metabolite linewidth during readout, by brain-only [delta]B₀ homogenization. This sequence-phase-optimal (SPO) shimming approach is demonstrated on four volunteer subjects using a commercial 3T MRI outfitted with a 32-channel integrated RF receive and local multi-coil shim array. This proposed sequence-phase-optimal shimming significantly improves brain-metabolite MRSI in vivo, as measured by lipid suppression, brain metabolite chemical shift, and line widths. The time required to compute patient specific SPO shims negligibly impacted scan time. Sequence-phase-optimal shimming reduced lipid energy in the brain volume across four subjects by 88%, improved NAA FWHM by 23%, and dramatically reduced lipid ringing artifacts in quantified NAA and Glutamate metabolites, without increasing scan time or SAR."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:title","label":"Title","values":["Sequence-phase optimal (SPO) [d̳e̳l̳t̳a̳]B₀ field control for lipid suppression and homogeneity for brain magnetic resonance spectroscopic imaging"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jacob White."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science","EECS"],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:creator":["Arango, Nicolas(Nicolas S.)"],"dc:date.accessioned":["2020-11-06T21:08:36Z"],"dc:date.available":["2020-11-06T21:08:36Z"],"dc:date.issued":["2020"],"dc:description":["Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, February, 2020","Cataloged from PDF version of thesis. [d̳e̳l̳t̳a̳] in title on title page appears as upper case Greek letter.","Includes bibliographical references (pages 33-35)."],"dc:description.abstract":["This work develops sequence-phase optimal (SPO) [delta]B₀ shimming methods to reduce lipid contamination and improve brain metabolite spectra in proton spectroscopic imaging. A rapidly reconfigurable 32-channel, local-multi-coil-shim-array is used to enhance lipid suppression and narrow metabolite linewidth in magnetic resonance spectroscopic imaging (MRSI) of the brain. The array is optimally reconfigured dynamically during each MRSI repetition period, first during the lipid-suppression phase, by widening the spectral gap between spatially separate lipid and metabolite regions, and then to narrow metabolite linewidth during readout, by brain-only [delta]B₀ homogenization. This sequence-phase-optimal (SPO) shimming approach is demonstrated on four volunteer subjects using a commercial 3T MRI outfitted with a 32-channel integrated RF receive and local multi-coil shim array. This proposed sequence-phase-optimal shimming significantly improves brain-metabolite MRSI in vivo, as measured by lipid suppression, brain metabolite chemical shift, and line widths. The time required to compute patient specific SPO shims negligibly impacted scan time. Sequence-phase-optimal shimming reduced lipid energy in the brain volume across four subjects by 88%, improved NAA FWHM by 23%, and dramatically reduced lipid ringing artifacts in quantified NAA and Glutamate metabolites, without increasing scan time or SAR."],"dc:description.degree":["S.M."],"dc:identifier.uri":["https://hdl.handle.net/1721.1/128411"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Sequence-phase optimal (SPO) [d̳e̳l̳t̳a̳]B₀ field control for lipid suppression and homogeneity for brain magnetic resonance spectroscopic imaging"],"dc:type":["Thesis"],"thesis:degree_name":["Master"]},"updated_at":"2026-07-22T22:22:22Z"}