Point cloud alignment in arm reconstruction for lymphedema detection by iterating pairwise ICP

Abstract

dc:description.abstract

Arm lymphedema is a debilitating condition characterized by a large swelling of the patient arms. This thesis describes a system for measuring arm volume with the goal of providing a cost-effective, reliable, easy to use, comfortable, and informative alternative to the tedious water displacement method or the expensive perometer. The device consists of 8 inexpensive positionally fixed realsense sr300 depth cameras in a frame that can be placed on a flat surface, and used to scan a patient's arm in order to build a 3D mesh that can be used to extract not only the total volume of the arm but also the volume of specific segments. A special focus is given to the method of global registration of each camera's depth image, where camera positions are iteratively adjusted by applying ICP between one camera's point cloud and the point cloud generated by all-but-that-one camera. The system is then validated by taking a set of measurements of a human arm and comparing the values against those obtained from the water displacement method, in addition to also measuring objects of known volume and comparing those values with the ground truth. Despite a large non constant percentage error between expected and obtained values, early experiments show an 5_ correlation value of .99 between the expected and measured volumes. While additional work and experiments are needed to guarantee the reliability of this proposed method in order to be used in a clinical setting, these early findings show the potential of using such a system in small clinics where both space and money limits the accessibility of a large or expensive device. Keywords: lymphedema, global registration, realsense, point cloud alignment, volume measurement, 3D reconstruction

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yordán López, Fernando A.
Advisor dc:contributor.advisor
  • Regina Barzilay.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/121644
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/121644

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Yordán López, Fernando A.. Point cloud alignment in arm reconstruction for lymphedema detection by iterating pairwise ICP. Massachusetts Institute of Technology, 2018. https://hdl.handle.net/1721.1/121644