Back to results

Massachusetts Institute of Technology

Characterization and optimization of signal and background for the time-resolving magnetic recoil spectrometer on the National Ignition Facility

Abstract

dc:description.abstract

The evolution of fuel assembly, hot-spot formation, and nuclear burn in an Inertial Confinement Fusion (ICF) implosion at the National Ignition Facility (NIF) can be quantified through time-resolved measurements of the neutron spectrum. This information will be obtained with the next-generation Magnetic Recoil Spectrometer (MRSt) that will measure the neutron spectrum (12-16 MeV) with high accuracy (~5%), unprecedented energy resolution (~100 keV) and, for the first time ever, time resolution (~20 ps). To successfully implement the MRSt on the NIF for this measurement, the signal and background distributions at the MRSt detector must be characterized; the detector response to the signal and background must be determined; and the shielding enclosing MRSt must be designed and implemented to reduce the background to the required level. These things have been done, which constitute the main results of this thesis. First, an MCNP model of the MRSt in the NIF target bay was implemented to assess the neutron- and gamma-background fluxes at an unshielded MRSt. Second, models of the MRSt-detector response to the signal protons (or deuterons), and neutron and gamma background were implemented to assess the signal-to-background (S/B) for the unshielded MRSt case. Using these models, it is discussed in this thesis that the combined neutron and gamma background in the MRSt data needs to be reduced 100-400 times. Third, a shielding design, consisting of polyethylene, tungsten, and stainless steel, fully enclosing the MRSt, was developed to reduce the background to the required level. This design reduces the background 100-200 times, and meets the requirement of S/B > 5 for the down-scattered-neutron measurement. Obviously, this design depends on the MRSt-detector response to the signal and background, and some minor adjustments to the design might be applied depending on the results from the upcoming measurements of the MRSt-detector response to signal and background. As the shielding design depends on the engineering design of the MRSt system, which has not been fully defined yet, some adjustments to the design will most likely be made when the MRSt engineering design is finalized.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wink, Christopher William
Advisor dc:contributor.advisor
  • Johan Frenje.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/112366
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/112366

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Wink, Christopher William. Characterization and optimization of signal and background for the time-resolving magnetic recoil spectrometer on the National Ignition Facility. Massachusetts Institute of Technology, 2017. http://hdl.handle.net/1721.1/112366