Loma Linda University
The Effect of Scan Settings on the Identification of Tooth Socket Lamina Dura Surface: A CBCT Study
Abstract
dc:description.abstract<p>Aim: Cone-beam computed tomography (CBCT) is becoming a common adjunct in orthodontic diagnosis and treatment, however several questions remain about the impact of surrounding anatomical structures and varying scan settings on the ability to delineate buccal bone and overall diagnostic quality of images produced. The aim of this study was to determine if adjacent structures with similar radiodensity and variable scan settings (field of view and voxel size) significantly impact the ability to accurately identify the tooth socket facial lamina dura, facial bone surface, facial bone margin, as well as the facial bone thickness measurement. Materials & Methods: CBCT scans (NewTom 5G) were performed on 2 fresh cadaver heads at 2 different time points, before (T1) and after (T2) tooth extraction, using 4 different scan settings that produced images in the decreasing order of clarity: 12x8 cm2 FOV at 100 μm voxel size (Group 1), 12x8 cm2 FOV at 150 μm voxel size (Group 2), 18x16 cm2 FOV at 150 μm voxel size (Group 3), and 18x16 cm2 FOV at 300μm voxel size (Group 4). The CBCT volumes were superimposed (Invivo 5.2) in pairs, before and after extraction, among the different scan settings (groups). Mid-sagittal images of the teeth were created and eleven total points along the external cortical border and facial lamina dura surface of each socket were identified. Absolute discrepancies between each pair were recorded and comparisons made using Wilcoxon Signed Rank Tests and Friedman’s Two-Way ANOVA (α = 0.05). Results: Although there were statistically significant differences (p < 0.05) in group and time-point discrepancies in 15 of 52 comparisons evaluated, the measured differences were low and likely clinically negligible. Conclusions: This study, with its own limitations, shows that the ability to accurately outline buccal bone, irrespective of the presence of the tooth structure, is not clinically significantly affected by the variation in FOV and voxel size of the CBCT images.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Orthodontics and Dentofacial Orthopedics
- Year
- 2015
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Carlucci, Erick
- Contributors dc:contributor
-
- Rungcharassaeng, Kitichai
- Caruso, Joseph M.
- Kan, Joseph Y. K.
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- This title appears here courtesy of the author, who has granted Loma Linda University a limited, non-exclusive right to make this publication available to the public. The author retains all other copyrights.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://scholarsrepository.llu.edu/etd/241
- OAI identifier oai:identifier
- oai:scholarsrepository.llu.edu:etd-1239