Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 137 for “"socket"”.

  1. Design and Implementation of User Level Socket Application Programming Interface with Socket Splitting and Mediation

    … have been limited by dependence on traditional sockets and TCP, which provide no support for modifying endpoints after connection setup. This forces applications to implement their own logic to reroute communications to take advantage of composable services or handle failover. Some solutions …

    calpoly Repository record for Design and Implementation of User Level Socket Application Programming Interface with Socket Splitting and Mediation (opens in a new tab)

  2. Prosthetic socket design : from a multi-indenter device for in vivo biomechanical tissue measurement to a quasi-passive transtibial socket interface

    The prosthetic socket, the mechanical interface between an amputated residuum and an external prosthesis, is of critical importance to the performance of a prosthetic limb system. Conventional prosthetic socket technology is derived using a non-quantitative, artisan methodology. Consequently, a …

    mit Repository record for Prosthetic socket design : from a multi-indenter device for in vivo biomechanical tissue measurement to a quasi-passive transtibial socket interface (opens in a new tab)

  3. Explorations into protein structure with the knob-socket model

    … packing of amino acid side-chains. The knob-socket model attempts to organize side-chain packing into tetrahedral packing motifs. This tetrahedral motif is characterized with a three residues on the same secondary structure forming the base of the tetrahedron packing with a side-chain from a …

    u-pacific Repository record for Explorations into protein structure with the knob-socket model (opens in a new tab)

  4. Design and analysis of a composite wire-socket attachment

    … the anchorage of a wire in a conical shaped socket using orthotropic materials. This model includes boundary conditions that are similar to the ones observed in the experiments. A parametric study is performed to obtain information on the ideal geometry of the anchor system. The results and …

    vt Repository record for Design and analysis of a composite wire-socket attachment (opens in a new tab)

  5. Sharing the love : a generic socket API for Hadoop Mapreduce

    … can integrate any file system which supports TCP sockets. By providing a file system agnostic API, future work with other file systems might provide ways for surpassing Hadoop 's current scalability limitations. Furthermore, the new API eliminates the need for customizing Hadoop's Java …

    u-pacific Repository record for Sharing the love : a generic socket API for Hadoop Mapreduce (opens in a new tab)

  6. An Analysis of PISCES (Platform Independent Socket ClassES) as a Teaching Tool.

    … APIs. One important set of communication APIs, socket APIs, are commonly used for coding C++ network applications. Socket APIs, unfortunately, are difficult to master, due to their procedural nature and inherent complexity. PISCES (Platform Independent Socket ClassES), is a C<sup>++</sup> socket

    etsu Repository record for An Analysis of PISCES (Platform Independent Socket ClassES) as a Teaching Tool. (opens in a new tab)

  7. Lubrication in the ball and socket joint of a swash plate mechanism

    The tribology of the ball and socket on the connecting rod in a swash plate engine is studied in the hydrodynamic regime. The engine operates at 1390rpm with an axial load on the rod as high as 1 x 10⁴N. The instantaneous load and kinematics from a previous study for a swash plate engine was used …

    mit Repository record for Lubrication in the ball and socket joint of a swash plate mechanism (opens in a new tab)

  8. Effects of a powered ankle prosthesis on shock absorption and residual limb/socket interface pressure

    … on both limbs, and discomfort at the stump/socket interface. State of the art; passive prostheses have improved many negative consequences associated with lower-limb loss, but we believe the limit of uninformed elastic prostheses has been reached. Further strides require a more biomimetic …

    mit Repository record for Effects of a powered ankle prosthesis on shock absorption and residual limb/socket interface pressure (opens in a new tab)

  9. The use of a novel residuum model to design a variable-impedance transtibial prosthetic socket

    … living with limb amputation, the prosthetic socket - the interface between the residuum and prosthesis - is the most critical component. When a socket is uncomfortable, especially due to poor fit, the quality of life for a patient is greatly hindered. However, conventional design of sockets …

    mit Repository record for The use of a novel residuum model to design a variable-impedance transtibial prosthetic socket (opens in a new tab)

  10. The Effect of Tooth Presence on Identification of Tooth Socket Lamina Dura Surface: A CBCT Study

    … bone surface, facial and lingual bone margins, socket apex, as well as in facial bone thickness measurement. Materials & Methods: Three fresh cadaver heads were scanned using a NewTom 5G CBCT at 0.100 mm voxel size at three time-points: before extraction (T1), after extraction and reinsertion …

    loma-linda Repository record for The Effect of Tooth Presence on Identification of Tooth Socket Lamina Dura Surface: A CBCT Study (opens in a new tab)

  11. Realization of a Measuring Device for Recordning the Relative Movement between Residual Limb and Prosthetic Socket

    … motion between residual limb and prosthetic socket is an indication of poor fit. Both the fabrication and fitting processes are highly subjective and a favorable result depends upon the technician's expertise. Although numerous methods exist to measure the relative motion, all have …

    vt Repository record for Realization of a Measuring Device for Recordning the Relative Movement between Residual Limb and Prosthetic Socket (opens in a new tab)

  12. The effect of socket design on the reliability of EMG signal transduction in trans-radial myoelectric prostheses

    … have suggested that the fit and/or design of the socket could be a contributing factor in the disruption of prosthesis control by introducing uncertainty and motion artefacts into the control system. However, there is currently no definitive prescription criterion that determines the effect that …

    salford

  13. The Effect of Scan Settings on the Identification of Tooth Socket Lamina Dura Surface: A CBCT Study

    … the ability to accurately identify the tooth socket facial lamina dura, facial bone surface, facial bone margin, as well as the facial bone thickness measurement. Materials & Methods: CBCT scans (NewTom 5G) were performed on 2 fresh cadaver heads at 2 different time points, before (T1) and …

    loma-linda Repository record for The Effect of Scan Settings on the Identification of Tooth Socket Lamina Dura Surface: A CBCT Study (opens in a new tab)

  14. Performance evaluation of an ensemble neural network system of estimating transtibial prosthetic socket pressures during standing, walking and condition perturbation.

    Providing suitable prosthetic sockets for the restoration of function following lower-limb amputation remains a significant issue in medical device prescription. Poorly designed sockets are associated with discomfort, poor quality function and injury, with quality linked to the capability of the …

    bournemouth Repository record for Performance evaluation of an ensemble neural network system of estimating transtibial prosthetic socket pressures during standing, walking and condition perturbation. (opens in a new tab)

  15. Competitive pricing and learning in CPU sockets

    … permanently or via a component called a socket. Intel defines the critical interfaces between the socket and the processor. Independent suppliers then manufacture the sockets and Intel validates the design of the sockets before they are sold to the original equipment manufacturers (OEMs). …

    mit Repository record for Competitive pricing and learning in CPU sockets (opens in a new tab)

  16. Advanced prototyping of variable impedance prosthetic sockets for trans-tibial amputees : polyjet matrix 3D printing of comfortable prosthetic sockets using digital anatomical data

    … design of a Variable Impedance Prosthetic (VIPr) socket for a transtibial amputee using computer-aided design and manufacturing (CAD/CAM). Compliant features are seamlessly integrated into a 3D printed socket to achieve lower interface peak pressures over bony protuberances by using …

    mit Repository record for Advanced prototyping of variable impedance prosthetic sockets for trans-tibial amputees : polyjet matrix 3D printing of comfortable prosthetic sockets using digital anatomical data (opens in a new tab)

  17. A Sensor for Three-Dimensional Limb-to-Prosthesis Interface Motion and Physiological Adaptations from Lower Extremity Prosthesis Use

    … tissue of the residual limb. As prosthesis socket fit is considered one of the most integral elements of increasing the likelihood a user adopts their artificial limb, it is crucial to understand how the limb interacts with the prosthesis at the contact interface. The individualized nature …

    washington Repository record for A Sensor for Three-Dimensional Limb-to-Prosthesis Interface Motion and Physiological Adaptations from Lower Extremity Prosthesis Use (opens in a new tab)

  18. Modeling and design of perforated prosthetic sockets ARCHM to increase heat transfer of residual limbs

    Heat build-up in prosthetic sockets is a significant problem experienced by many amputees in America, with no central solution in sight. Heat and discomfort accounts for over 70% of problems experienced by lower limb amputees in America. Although there have been advances in prosthetics in the …

    mit Repository record for Modeling and design of perforated prosthetic sockets ARCHM to increase heat transfer of residual limbs (opens in a new tab)

  19. A new method of termination for heavy-duty synthetic rope fibres

    … The new method, "The Vaseghi Stress Relief Socket", has been proposed to improve the high stress concentration areas inside sockets and move failure points along the rope. The new method has increasedthe tensile performance of existing ropes up to 13%. It should also be addedthat the ropes …

    bournemouth Repository record for A new method of termination for heavy-duty synthetic rope fibres (opens in a new tab)

Page 1 of 7