Back to results

Georgia Institute of Technology

Minimally invasive assessment of lymphatic pumping pressure using near infrared imaging

Abstract

dc:description.abstract

Although the major functions of the lymphatic system are fairly well defined, its vasculature has yet to be well characterized in comparison to its blood vasculature counterpart. Recent advances in optical imaging techniques have allowed for more detailed and quantitative evaluations of lymph flow dynamics and mechanism. A rat tail is often used for investigations of lymph flow because of the simple geometry, superficial nature, and disease progression models of its collecting lymphatic vessels. In this study, a pressure cuff system was fabricated and coupled with an existing functional near infrared (NIR) imaging system to measure the overall pumping pressure of the lymphatic vessels of a rat tail. In addition to adapting the system for use on rodents, previous systems used for measuring lymphatic pumping pressure in humans were improved upon in several ways. The system defined here utilizes closed-loop feedback control of pressure application at smaller, more precise intervals. Using this device, a significant difference in lymphatic vessel pumping pressure was detected between a control case and a treatment case in which a vasoactive substance with a nitric oxide donor (GTNO ointment) was applied to the tail. Although it is known that nitric oxide plays a crucial physiologic role in propagation of flow through lymphatic vessels, this study has quantified its significant pharmacological reduction of pumping pressure for the first time.

Degree

thesis:*
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Akin, Ryan E.
Advisor dc:contributor.advisor
  • Dixon, J. Brandon
Committee members dc:contributor.committeemember
  • Ku, David N.
  • Rudolph L. Gleason

Subjects

dc:subject × 8

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/47536
OAI identifier oai:identifier
oai:repository.gatech.edu:1853/47536

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-07-27
Source record
OAI-PMH GetRecord
citation

Akin, Ryan E.. Minimally invasive assessment of lymphatic pumping pressure using near infrared imaging. Georgia Institute of Technology, 2013. http://hdl.handle.net/1853/47536