Back to results

University of Dundee

An analysis of the utility of quantitative faecal immunochemical tests in screening and symptomatic populations

Abstract

dc:description.abstract

<b>Background</b>: It has been demonstrated, in 4 large randomised control trials (RCT), that screening for colorectal cancer (CRC) using annual or biennial guaiac faecal occult blood tests (gFOBT) reduces mortality and incidence. The faecal immunochemical test (FIT) uses technology that is analytically more sensitive and specific for human haemoglobin (Hb) than gFOBT.<b><br/></b><b><br/></b><b>Methods</b>: An evaluation of the OC-Sensor Diana quantitative FIT analyser and prospective analysis of a single estimate of faecal haemoglobin concentration (f-Hb) in two clinical settings; the Scottish Bowel Screening Programme and patients referred from primary care to endoscopy services.<b><br/></b><b><br/></b><b>Results</b>: Uptake, in the cohort offered screening with FIT as a first-line test, was 4.8% higher than that seen contemporaneously in the Scottish Bowel Screening Programme. This returned to pre study levels when the study ceased and gFOBT was reintroduced. The cohort offered quantitative FIT had a positivity of 2.4% compared to 2.1% in the programme overall. Clinical outcomes, during the evaluation period, in the study cohort and the screening programme were similar.<br/><br/>40,125 participants returned a FIT sample device and 38,720 had their f-Hb measured. An observational study of f-Hb by sex and age, using the 97.5th percentile as a potential upper reference limit, and 90% confidence intervals (CI) showed 519 ng Hb/ml buffer (90% CI: 468 – 575) for men and 283 ng Hb/ml buffer (90% CI: 257 – 316) for women. When the data was partitioned by age quintile, f-Hb increased with age in both sexes.<br/><br/>Quantitative FIT and endoscopy were completed by 280 patients referred from primary care for endoscopy (median age: 63 years, range: 18 to 84 years), 59.6% were female. Six (2.1%) participants had CRC, 23 (8.2%) high-risk adenoma (HRA: &gt;3 adenomas or any &gt; 1 cm), 31 (11.1%) low-risk adenoma (LRA), and 26 (9.3%) inflammatory bowel disease (IBD) as the most serious diagnosis. Those with CRC had median f-Hb of &gt; 1000 ng Hb/ml buffer. Using f-Hb with a cut-off of 50 ng Hb/ml buffer, negative predictive values of 100%, 94.4%, 93.4% and 93.9% were found for CRC, HRA, LRA and IBD.<b><br/></b><b><br/></b><b>Conclusions</b>: The introduction of quantitative FIT into population screening and symptomatic settings has the potential to optimise referral for endoscopy for those who have evidence of small amounts of bleeding, thereby improving outcomes and reducing the current burden on endoscopy services.

Degree

thesis:*
Name dc:type.qualificationname
Doctor of Philosophy
Level dc:type.qualificationlevel
Doctoral Thesis
Grantor dc:publisher.institution
University of Dundee
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • McDonald, Paula Jane
Advisors dc:contributor.advisor
  • Steele, Robert
  • Bartlett, Bill

Subjects

dc:subject × 1

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
oai:discovery.dundee.ac.uk:studenttheses/679a6b7a-1dfa-4e89-87f3-7a2014b9a551
OAI identifier oai:identifier
oai:discovery.dundee.ac.uk:studenttheses/679a6b7a-1dfa-4e89-87f3-7a2014b9a551

Chain of custody

source
Harvested from
University of Dundee
Base URL
discovery.dundee.ac.uk/ws/oai
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

McDonald, Paula Jane. An analysis of the utility of quantitative faecal immunochemical tests in screening and symptomatic populations. Doctoral Thesis thesis, University of Dundee, 2016. https://discovery.dundee.ac.uk/en/studentTheses/679a6b7a-1dfa-4e89-87f3-7a2014b9a551