Back to results

Dominican University of California

Qualify Microplate Reader’s Specification and Establish the Acceptance Criteria for Modified PicoGreen Kit in Measuring cell-free DNA Concentration in Clinical Laboratory

Abstract

dc:description.abstract

<p>Cell-free DNA (cfDNA) is an emerging biomarker that researchers are utilizing to detect diseases in patients, allowing physicians to accurately diagnose and treat patients at the individual level. A few applications that utilize cfDNA to detect diseases in IVD (in-vitro diagnostics) are non-invasive prenatal testing, circulating tumor DNA markers, transplant rejection using donor derived cfDNA and microbial cfDNA in identifying infectious agents (3,4,5,6). The current challenge in our laboratory is to measure cfDNA concentration from minimal volume of plasma after the extraction methods. Different methods of extraction yield various concentrations of dsDNA. Our laboratory develops the use of a modified PicoGreen kits and Biotek’s microplate reader to measure cfDNA concentration. This assay is being qualified to allow the laboratory to assess the yields of dsDNA after extraction method. Qualification includes performance for linearity, accuracy, precision and stability of standards. The study of this modified PicoGreen assay establishes the linearity assay range from 1ng/mL to 1200ng/mL (equivalent to 0.017 – 20 ng/uL of dsDNA) with the imprecision less than 20%. The accuracy study was verified using commercial material with a known concentration and a comparison method with Agilent’s Tape-station. The standards of this assay have 14 days stability. The modified PicoGreen assay’s performance metrics are evaluated and determined to be acceptable for laboratory’s purposes, to use as quality indicator in assessing the yield of dsDNA from laboratory’s extraction method.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's Thesis (Campus only Access)
Discipline thesis:degree_discipline
Clinical Laboratory Sciences
Year dc:date.available
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Quach, Huy T
Contributors dc:contributor
  • Marla Vaughn
  • Maria C. DeSousa, JD, MPA, CLS

Subjects

dc:subject × 4

Identifiers

dc:identifier.*
Repository record dc:identifier
https://scholar.dominican.edu/masters-theses/325
OAI identifier oai:identifier
oai:scholar.dominican.edu:masters-theses-1350

Chain of custody

source
Harvested from
Dominican University of California
Base URL
scholar.dominican.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Quach, Huy T. Qualify Microplate Reader’s Specification and Establish the Acceptance Criteria for Modified PicoGreen Kit in Measuring cell-free DNA Concentration in Clinical Laboratory. Master's Thesis (Campus only Access) thesis, 2018. https://scholar.dominican.edu/masters-theses/325