Back to results

Department of Chemistry

The development of physico-chemical quality control methods for Haemophilus influenzae type b vaccine production

Abstract

dc:description.abstract

The development of a low cost Haemophilus influenzaetype b (Hib) manufacturing platform at The Biovac Institute (TBI) required analytical method development in parallel with the production process development. Technology transfer enabled TBI to develop Hib vaccine production which could lead to the development of vaccine manufacturing capacity in subSaharan Africa. Initial studies were conducted in the Research and Development (R&D) department from where the process was transferred to the Good Manufacturing Process (GMP) environments of the Production and Quality Control departments respectively. Scaling of the development process to a process commercially viable required the development of additional quality control test methods. The quality control of Hib is performed by characterisation of the manufactured batch using physico-chemical analysis. The data generated are compared against that of a successful clinical trial batch. Animal based models for the potency and safety tests of Hib are ineffective. Chromatographic methods of analysis are often used in the pharmaceutical and biotechnological industry. Gas chromatography with flame ionisation detection (GC-FID) is a conventional technique used for the analysis of volatile analytes. The analysis of process residuals ethanol and ethylene glycol were performed using headspace or direct injection GC-FID analysis. Ethylene glycol, a non-volatile solvent, was chemically dried after which it was derivatised with a trimethylsilylating reagent. In addition, a method was developed to determine polyribosylribitolphosphate. Samples were dried by means of lyophilisation and then subjected to methanolysis to yield methyl glycosides. A trimethylsilylating reagent was used to volatilise the analyte and analysis was performed using GC-FID with direct injection. The use of internal standards throughout the sample preparation processes minimised errors due to sample handling, processing or injector reproducibility. Analytical method validation parameters were applied to the developed methods.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Chemistry
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Behr,Heinrich Richard
Advisor dc:contributor.advisor
  • Ravenscroft, Neil

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/6581
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/6581

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Behr,Heinrich Richard. The development of physico-chemical quality control methods for Haemophilus influenzae type b vaccine production. Department of Chemistry, 2013. http://hdl.handle.net/11427/6581