Back to results

Division of Biomedical Engineering

A multi-channel system for use in cardiac electrophysiologic studies

Abstract

dc:description.abstract

The location of accessory pathways in Wolff-Parkinson-White syndrome patients is performed manually during open heart surgery at Groote Schuur Hospital, using a hand-held roving electrode. This manual procedure is slow and tedious, prolonging the operation and the time for which the patient remains on cardiac bypass. A multichannel electrogram acquisition and display system with a storage facility would significantly reduce the time taken and improve the reliability of locating the accessory pathways. Having considered a number of currently available cardiac mapping systems it was decided that a new system be developed for specific application within Groote Schuur Hospital. The main design goals of this system are to improve accuracy, increase reliability and enhance the speed of the entire mapping procedure with direct benefit to staff and patients. The system is based on an IBM compatible computer and allows for the acquisition of a maximum of thirty-two electrogram inputs. A typical configuration would acquire twenty epicardial, two references (one each from atrium and ventricle), one roving electrode and two surface lead signals. The epicardial signals are obtained from a custom-built electrode belt which is placed around the heart over the atrioventricular groove. The project includes the development of front-end hardware and software for processing, display and storage of electrogram signals. The relative activation times of the signals are displayed under software control in order to facilitate the location of any accessory pathway(s).

Degree

thesis:*
Grantor dc:publisher.institution
Division of Biomedical Engineering
Year dc:date.issued
1991

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wyatt, Barry Neil
Advisors dc:contributor.advisor
  • Poluta, Mladen
  • Millar, Rob Scott

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/27151
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/27151

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Wyatt, Barry Neil. A multi-channel system for use in cardiac electrophysiologic studies. Division of Biomedical Engineering, 1991. http://hdl.handle.net/11427/27151