Back to results

Division of Medical Microbiology

Improving point-of-care diagnosis of tuberculosis: development and evaluation of novel technologies

Abstract

dc:description.abstract

With an estimated third of all tuberculosis (TB) cases being missed, the need to develop rapid, simple and accurate diagnostic tests is critical. The last five years has seen an unprecedented activity in the development of a range of new tests. However, a major concern is that not all marketed TB tests have been assessed rigorously, particularly in terms of diagnostic accuracy, robustness under operational conditions in the field, and practical usefulness. This dissertation comprises a compilation of diagnostic clinical studies of novel point-of-care tests, namely a chemiresistive "TB breath-analyser"; a lipoarabinomannan (LAM) urine dipstick, and an adaptation of the Xpert®MTB/RIF assay for use on blood. Lastly, there is a modification of the sputum collection device (SCD) to enable specimen processing without the requirement of a biosafety cabinet. The chemiresistive sensor, which detects volatile organic compounds released by Mycobacterium tuberculosis in a patient's breath, demonstrated a high sensitivity (100%) and specificity (92%) for distinguishing patients with active TB from healthy controls. However, sensitivity (74%) and specificity (63%) were lower when the culture-negative participant group was compared to the culture-positive participants. The test shows potential as a useful screening test for TB with further refinement of the sensor technology. The LAM dipstick was shown to be useful in hospitalised HIV-infected patients with CD4 T-cell counts <200 cells/μL reinforcing the data from other studies. Although the blood Xpert®MTB/RIF assay showed some utility in diagnosis of TB in hospitalised patients with very advanced HIV, given the poor sensitivity and specificity, and the requirement for specialised equipment as well as a large volume of blood for testing, it is unlikely that Xpert®MTB/RIF testing on blood will contribute much over other existing diagnostics in resource-limited settings. Finally, the redesigned SCD offers a solution to biosafety concerns with minimal impact on patient acceptability and clinical care.

Degree

thesis:*
Grantor dc:publisher.institution
Division of Medical Microbiology
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Moodley, Vineshree Mischka
Advisors dc:contributor.advisor
  • Nicol, Mark P
  • Dorman, Susan E

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/25439
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/25439

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Moodley, Vineshree Mischka. Improving point-of-care diagnosis of tuberculosis: development and evaluation of novel technologies. Division of Medical Microbiology, 2017. http://hdl.handle.net/11427/25439