Back to results

Division of Chemical Pathology

Validation of an adjusted calcium formula using the Roche calcium (NMBATPA) and albumin (BCG) methods at Groote Schuur Hospital

Abstract

dc:description.abstract

ABSTRACT: Validation of an adjusted calcium formula using the Roche calcium (NMBATPA) and albumin (BCG) methods at Groote Schuur Hospital Introduction: Most laboratories continue to adjust serum total calcium (tCa) concentration for serum albumin as a surrogate marker of calcium status, despite the availability of ionised calcium (iCa) measurement. Current recommendations by the Association for Clinical Biochemistry and Laboratory Medicine (ACB) advocate that laboratories should use formulae specific for their tCa and albumin methods and analytical platforms. The National Health Laboratory Service at Groote Schuur Hospital (GSH) undertook to investigate this recommendation. An adjusted calcium (aCa) formula specific for the Roche serum tCa and albumin methods was derived from 3131 patients. We investigated the validity and clinical utility of this locally derived aCa formula. Methods: The tCa, albumin and iCa were analysed in blood from 162 inpatients and outpatients at GSH. Corrected calcium (cCa) was calculated using the Payne cCa formula, and aCa was calculated with the new aCa formula. Patients were classified as hypo-, normoor hypercalcaemic using iCa, tCa, cCa and aCa measurements. Cohen's kappa statistic, loglinear and logistic regression models and interclass and concordance correlation coefficients were used to assess agreement between tCa, Payne cCa and aCa against iCa (gold standard). Agreement was further assessed according to renal status and albumin concentrations. Results: The aCa demonstrated good correlation with iCa, but its performance was not significantly better than tCa or Payne cCa in correctly classifying calcium status. Furthermore, albumin concentration was demonstrated to predict the performance of the calcium status classification by the aCa and cCa formulae, irrespective of renal status. Conclusion: The laboratory-specific aCa formula did not perform significantly better than tCa and the Payne cCa formula. This implies that aCa does not add value over tCa where iCa measurements are not readily available.

Degree

thesis:*
Grantor dc:publisher.institution
Division of Chemical Pathology
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ndlovu, Mbali
Advisors dc:contributor.advisor
  • Omar, Fierdoz
  • Vreede, Helena

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/25381
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/25381

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Ndlovu, Mbali. Validation of an adjusted calcium formula using the Roche calcium (NMBATPA) and albumin (BCG) methods at Groote Schuur Hospital. Division of Chemical Pathology, 2017. http://hdl.handle.net/11427/25381