The utility of occlusion of the pulse oximeter trace in the estimation of systolic blood pressure during spinal anaesthesia for caesarean section: the effect of body mass index

Abstract

dc:description.abstract

Background: We compared the accuracy and precision of estimation of the systolic blood pressure (SBP) by disappearance of the pulse oximeter trace (DOT), with noninvasive blood pressure (NIBP) measurement, across the range of body mass index (BMI), during spinal anaesthesia (SA) for caesarean section (CS). Methods: Three groups of 25 parturients were recruited, with BMI of < 30- (Group 1), 30-40- (Group 2), and > 40 kg/m2 (Group 3) respectively. SBP was measured using the DASH® 3000 monitor (GE Health Care, UK) NIBP monitor, placed on the same arm as the pulse oximeter probe. Estimations of SBP were done before- and 5 minutes after induction of SA, during cuff inflation and deflation. The times taken for the estimations and the actual NIBP measurements were noted. Bland and Altman analysis was performed and the correlation coefficient estimated. Results: Concerning the most clinically relevant estimation, namely SBP during inflation post-SA: For Groups 1, 2 and 3, r = 0.56, 0.74 and 0.91; bias = -0.4, -2.9 and 0.8 mmHg, and limits of agreement = -27.7 to 26.9, -27.7 to 21.9 and -15.9 to 17.5 mmHg respectively. The mean (SD) time required for estimation of the SBP during inflation post- SA was 7.5 (1.1) s, 11.8 (3.8) s and 16.8 (4.2) s in the Groups 1, 2 and 3 respectively. The mean (SD) time required for measurement of post-SA SBP during inflations in Groups 1, 2 and 3, was 30.3 (13.1) s, 41.3 (10.2) s and 49.8 (14.6) respectively. In the post-SA period, mean time saved by estimating SBP during inflation was approximately 28.5 seconds, compared with 9 seconds during deflation. The time saved in Groups 1, 2 and 3 was 22.8 (13.2) s, 30.0 (11.6) s and 33.0 (15.6) s respectively. In the BMI > 40 kg/m2 group, the percentage error is ±13% of the mean systolic blood pressure observed, and the absolute error is ±16 mmHg, compared to ±27 mmHg in the normal BMI group. Conclusion: Post-SA estimation of SBP during cuff inflation in morbidly obese patients is more accurate and precise than in the other BMI Groups. Time to estimation is shorter than measurement by a clinically relevant period (33 s). This should improve patient safety in morbidly obese parturients.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Anaesthesia
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Samuel, Theresa
Advisor dc:contributor.advisor
  • Dyer, Robert A

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/23653
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/23653

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Samuel, Theresa. The utility of occlusion of the pulse oximeter trace in the estimation of systolic blood pressure during spinal anaesthesia for caesarean section: the effect of body mass index. Department of Anaesthesia, 2016. http://hdl.handle.net/11427/23653