Back to results

University of Cambridge

Fatigue life modelling of anisotropic styrenic block copolymers for a prosthetic heart valve application

Abstract

dc:description.abstract

This thesis describes a fatigue lifetime prediction model for anisotropic styrenic block copolymers. A shortlist of cylinder forming block copolymers has been tested for a flexible leaflet aortic prosthetic heart valve, designed to mimic the native structure of the aortic leaflet. Polymeric valves have the potential to overcome the limit of current available prosthesis, however no such valve is available clinically at present. Durability and calcification are among the main issues with polymeric valves designed and tested previously. The solution to these problems resides in the correct choice of material. In this study, a fatigue model was validated for anisotropic styrenic block copolymers to assist in the selection of the most durable material. The prediction is based on a unified approach of crack growth and nucleation tests. The model correctly predicted the lifetime of the material with same microstructure orientation, thickness and geometry. Material comparison based on the fatigue results highlighted the most durable material, a poly(styrene-b-butadiene-b-styrene) with 20% weight of styrene. The material was manufactured into a valve, which comfortably exceeded ISO standards for in vitro durability and hydrodynamic perfomance. Calcification and its effect on durability were tested. The calcification test was conducted in a simulated body fluid solution. Calcium levels on the styrenic block copolymers were significantly lower than on bovine pericardium, which is one of the materials used in clinical prosthesis. Durability of the calcified valve was not affected, indicating that the selected materials have great potential for biomedical applications. Finally, the effect of heparin coating was measured for both durability and calcification. The coating increased the level of calcification but did not affect durability in either unitensile specimens or valve prototypes.

Degree

thesis:*
Name dc:type.qualificationname
Doctor of Philosophy (PhD)
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
University of Cambridge
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Biral, Eugenia
Advisor dc:contributor.advisor
  • Moggridge, Geoff D

Subjects

dc:subject × 3

Rights

dc:rights
Language dc:language
eng

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.17863/CAM.74542
OAI identifier oai:identifier
oai:www.repository.cam.ac.uk:1810/327088

Chain of custody

source
Harvested from
Cambridge University
Base URL
api.repository.cam.ac.uk/server/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Biral, Eugenia. Fatigue life modelling of anisotropic styrenic block copolymers for a prosthetic heart valve application. Doctoral thesis, University of Cambridge, 2021. https://doi.org/10.17863/CAM.74542