Particle-modified Surface Plasmon Resonance Biosensor

Abstract

dc:description.abstract

Surface plasmon resonance (SPR) biosensors have attracted great attention in scientific research in the past three decades. Extensive studies on the immobilisation of biorecognition elements have been conducted in pursuit of higher sensitivity, but trialled formats have focussed on a thin layer modification next to the plasmon film, which usually requires in situ derivatization. This thesis investigates an ‘off-chip’ immobilisation strategy for SPR biosensing using silica particles and considers the implications of a particle-modified evanescent field on the signal amplitude and kinetics, for an exemplar affinity binding between immobilised IgG and its anti-IgG complement. Submicron silica particles were synthesized as carriers for the bio-recognition elements. They were then immobilised to form a sub-monolayer on the gold film of an SPR biosensor using two methods: thiolsilane coupling and physical adsorption aided by mechanical pressure. The bio-sensitivity towards an antigen/antibody interaction was lower than an SPR biosensor with an alkanethiolate SAM due to the difference in ligand capacity and position in the evanescent field. The binding kinetics of antigen/antibody pair was found to follow the Langmuir model closely in a continuous flow configuration but was heavily limited by the mass transport from the bulk to the sensor surface in a stop-flow configuration. A packed channel configuration was designed with larger gel particles as ligand carriers, packed on top of a gold film to create a column-modified SPR biosensor. This sensor has comparable bio-sensitivity to the previous sub-monolayer particle-modified systems, but the binding and dissociation of the analyte was heavily dependent on mass transport and binding equilibria across the column. A bi-directional diffusion mechanism was proposed based on a two-compartment mass transport model and the expanded model fitted well with the experimental data. The column-modified sensor was also studied by SPR imaging and analyte band formation was observed and analysed. Using the lateral resolution, a multiplexing particle column configuration was explored, and its potential in distinguishing a multicomponent analyte.

Degree

thesis:*
Name dc:type.qualificationname
Doctor of Philosophy (PhD)
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
University of Cambridge
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Du, Yao
Advisor dc:contributor.advisor
  • Hall, Lisa

Subjects

dc:subject × 4

Rights

dc:rights
Language dc:language
en

Identifiers

dc:identifier.*
Author Identifier
0000-0002-6431-1495
OAI identifier oai:identifier
oai:www.repository.cam.ac.uk:1810/289388

Chain of custody

source
Harvested from
Cambridge University
Base URL
api.repository.cam.ac.uk/server/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Du, Yao. Particle-modified Surface Plasmon Resonance Biosensor. Doctoral thesis, University of Cambridge, 2018. https://doi.org/10.17863/CAM.36636