Back to results

University of Cambridge

Mathematical approaches for the clinical translation of hyperpolarised 13C imaging in oncology

Abstract

dc:description.abstract

Dissolution dynamic nuclear polarisation is an emerging clinical technique which enables the metabolism of hyperpolarised 13C-labelled molecules to be dynamically and non- invasively imaged in tissue. The first molecule to gain clinical approval is [1-13C]pyruvate, the conversion of which to [1-13C]lactate has been shown to detect early treatment re- sponse in cancers and correlate with tumour grade. As the technique has recently been translated into humans, accurate and reliable quantitative methods are required in order to detect, analyse and compare regions of altered metabolism in patients. Furthermore, there is a requirement to understand the biological processes which govern lactate pro- duction in tumours in order to draw reliable conclusions from this data. This work begins with a comprehensive analysis of the quantitative methods which have previously been applied to hyperpolarised 13C data and compares these to some novel approaches. The most appropriate kinetic model to apply to hyperpolarised data is determined and some simple, robust quantitative metrics are identified which are suitable for clinical use. A means of automatically segmenting 5D hyperpolarised imaging data using a fuzzy Markov random field approach is presented in order to reliably identify regions of abnormal metabolic activity. The utility of the algorithm is demonstrated on both in silico and animal data. To gain insight into the processes driving lactate metabolism, a mathematical model is developed which is capable of simulating tumour growth and treatment response under a range of metabolic and tissue conditions, focusing on the interaction between tumour and stroma. Finally, hyperpolarised 13C-pyruvate imaging data from the first human subjects to be imaged in Cambridge is analysed. The ability to detect and quantify lactate production in patients is demonstrated through application of the methods derived in earlier chapters. The mathematical approaches presented in this work have the potential to inform both the analysis and interpretation of clinical hyperpolarised 13C imaging data and to aid in the clinical translation of this technique.

Degree

thesis:*
Name dc:type.qualificationname
Doctor of Philosophy (PhD)
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
University of Cambridge
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Daniels, Charlotte Jane
Advisors dc:contributor.advisor
  • Gallagher, Ferdia
  • Anderson, Alexander

Subjects

dc:subject × 12

Rights

dc:rights
Language dc:language
en

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:www.repository.cam.ac.uk:1810/275339

Chain of custody

source
Harvested from
Cambridge University
Base URL
api.repository.cam.ac.uk/server/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Daniels, Charlotte Jane. Mathematical approaches for the clinical translation of hyperpolarised 13C imaging in oncology. Doctoral thesis, University of Cambridge, 2018. https://doi.org/10.17863/CAM.22529