State University of New York at Buffalo
Real Time Prostate Motion Tracking Using the Portal Imaging Device in Radiation Therapy
Abstract
dc:description.abstractIntrafractional motion management is the key step in image-guided radiation therapy. Prostate location can change vastly during treatment. This work is to provide a way to implement and facilitate real-time MV tumor surrogate tracking of the fiducial marker implanted for prostate cancer treatment. An in-house program was developed to automatically extract fiducial marker locations based on patient planning CT images. The corresponding location coordinates were used to determine the possibility of true marker presence at that location with the approved radiation treatment plan. Various ways and inter-fiducial-marker distance of implanted markers were investigated to pinpoint the optimal combination for better tracking the fiducial markers using the MV imager. An optimal pattern and corresponding location range for better tracking the fiducial markers were recommended based on the calculation results. Experimental verification was performed with a homogenous bolus phantom. Three different MLC modulated arc therapy plans were randomly selected to verify the predicted and measured detectability score for five fiducial marker patterns (from all four pattern categories). All the MV-cine images were recorded and analyzed. The results of predicted and measured detectability score matched well with each other, confirming the suggested pattern and location range proposed in this study. Lastly, a dose perturbation algorithm was examined. Different types of errors were introduced to radiation therapy plans. The modified plans were measured by ArcCHECK QA device to evaluate the dosimetry impact of the induced error.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2018
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ma, Tianjun; 0000-0001-5670-8487
- Contributors dc:contributor
-
- Podgorsak, Matthew
- Radiology
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Copyright retained by author.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/77930