Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 65 for “"nails"”.

  1. Single shear vs. double shear for nails in lateral loading

    … of the lateral load-carrying capacity of nails in single and double shear, and (2) to develop a basis for structural design data for laterally loaded nails in double shear applicable whenever deformation is a governing factor, such as in joints of trussed rafters. The test loads at or near …

    vt Repository record for Single shear vs. double shear for nails in lateral loading (opens in a new tab)

  2. Evaluation of the Ability of Adhesives to Substitute Nails in Wooden Block Pallets

    … are helically or annularly threaded pallet nails. Pallet nails create a strong durable connection and increase manufacturing efficiency for a low cost. However, nails can also cause iron staining, wood splitting, and when exposed can cause product damage or personnel injury. Using adhesives …

    vt Repository record for Evaluation of the Ability of Adhesives to Substitute Nails in Wooden Block Pallets (opens in a new tab)

  3. Methodology to predict the strength and stiffness of red alder block pallet connections fastened with helically threaded nails

    … side member thicknesses and four types of nails. Also, the influence of other specific variables on joint performance was evaluated including friction, pattern, moisture content, number of nails per joint, specific gravity, and rate of loading. In total, 23 sets of nailed joint specimens, …

    vt Repository record for Methodology to predict the strength and stiffness of red alder block pallet connections fastened with helically threaded nails (opens in a new tab)

  4. “Removing the nail from the coffin'' outcomes of intramedullary nailing of femur fractures: a comparison of anterograde- and retrograde nails

    … population. In the past, intramedullary femur nails were primarily performed utilising the anterograde approach (AFN). Recently, the retrograde approach (RFN) has become an attractive alternative option. The retrograde approach requires no traction table during surgery, a viable solution where, …

    cape-town Repository record for “Removing the nail from the coffin'' outcomes of intramedullary nailing of femur fractures: a comparison of anterograde- and retrograde nails (opens in a new tab)

  5. The Influence of the Size and Design of Nails On Their Efficiency With Respect to Driving and Pulling From Various Species of Wood

    … study of the influence of the size and design of nails on their efficiency with respect to driving and pulling from various species of wood. The study was made at the Forest Products Laboratory of the United States Forest Services in cooperation with the American Steel and Wire Company, primarily …

    sdstate Repository record for The Influence of the Size and Design of Nails On Their Efficiency With Respect to Driving and Pulling From Various Species of Wood (opens in a new tab)

  6. Relationships between MIBANT bend angles and selected material properties of pallet fasteners

    … Static yield strength values for pallet nails were found to values (p > 0.0001 be linearly related to the dynamic 2 and R² = 0.950) and hence MIBANT bend angles. Static yield strength values were also related to MIBANT bend angles (p > 0.209 and R² = 0.896) for staples. The Vickers …

    vt Repository record for Relationships between MIBANT bend angles and selected material properties of pallet fasteners (opens in a new tab)

  7. Evaluation of improved stevedore pallet

    … of two designs assembled with four different nails. Special consideration was given to Brazilian situations in the light of the interest of the author in the industrial potential of Brazil. The pallets of improved design had their top and bottom leading-edge deckboards backed up by follow-up …

    vt Repository record for Evaluation of improved stevedore pallet (opens in a new tab)

  8. Ενδομυελική εφαρμογή δύο ήλων Ender's εις κατάγματα κνήμης

    WE USED TWO ENDR'S NAILS IN TIBIAL FRACTURES IN 57 PATIENTS WITH 59 FRACTURES. WE CREATED TEN EXPERIMENTAL MODELS AND TESTED THE METHOD IN NAT.TECHN. UNIVERSITY, ATHENS. THE AVERAGE HEALING TIME WAS 3,13 MONTHS WITH EXCELLENT RESULTS IN 48 FRACTURES. VERY GOOD RESULTS IN 6, WITH GOOD IN 4 AND WITH …

    greece Repository record for Ενδομυελική εφαρμογή δύο ήλων Ender's εις κατάγματα κνήμης (opens in a new tab)

  9. Induktion und Prophylaxe Implantat assoziierter Knocheninfektionen am Modell eines antiinfektiv beschichteten Marknagels

    … biocompatibility, in a group of eleven rabbits nails uncoated (n=5) or nails coated with PDLLA and gentamicin (n=6) were implanted into the femur. Serum gentamicin was determined after 12, 24, 48 hours and then weekly. Follow-up was six weeks. After sacrifice the femora were examined by …

    lmu-germany Repository record for Induktion und Prophylaxe Implantat assoziierter Knocheninfektionen am Modell eines antiinfektiv beschichteten Marknagels (opens in a new tab)

  10. Evaluation of the KanchanTM Arsenic Filter under various water quality conditions of the Nawalparasi District, Nepal

    … the integration of locally available iron nails into a BioSand Filter setup. Since 2002, the KAF filter has been successfully disseminated in approximately 24,000 Nepali households. However, recent studies have indicated that under certain raw water conditions, the KAF may inadequately …

    mit Repository record for Evaluation of the KanchanTM Arsenic Filter under various water quality conditions of the Nawalparasi District, Nepal (opens in a new tab)

  11. Experimental analysis of king-post truss with semi-rigid joints

    … plywood gusset plates using helically threaded nails to form roof trusses has been widely developed in recent years. Actually, the nailed member has proven to be extremely strong and stiff, but it is not perfectly rigid. The effect of non-rigidity of joints in resisting bending and thrust are …

    vt Repository record for Experimental analysis of king-post truss with semi-rigid joints (opens in a new tab)

  12. Rankų higienos reikalavimų laikymosi vertinimas palaikomojo gydymo ir slaugos ligoninėse /

    … The most common non-compliances were varnished nails and wearing a watch. Compliance with hand hygiene requirements, as measured by hand hygiene moments, was 50,43 %. Compliance was highest after contact with the patient‘s body fluids (79,17 %) and lowest before contact with the patient (42,75 …

    vilnius Repository record for Rankų higienos reikalavimų laikymosi vertinimas palaikomojo gydymo ir slaugos ligoninėse / (opens in a new tab)

  13. Evaluation of the joint performance estimates within the PDS durability procedure

    … the delayed withdrawal performance of threaded nails. An improved relationship was derived for helically threaded, twisted square wire and annularly threaded nails which had the additional advantage of being sensitive to lumber moisture content both at the time of joint assembly and at the time …

    vt Repository record for Evaluation of the joint performance estimates within the PDS durability procedure (opens in a new tab)

  14. Experimental analysis of the efficiency of carbon fiber anchors applied over CFRP to firebrick bonded joints

    … the composite and fastened in the support like nails . Research on the use of anchors for masonry supports has been limited and there are no experimental analyses related to the design and the placement of fiber anchors. The aim of this thesis is to provide experimental data to quantify the …

    catania Repository record for Experimental analysis of the efficiency of carbon fiber anchors applied over CFRP to firebrick bonded joints (opens in a new tab)

  15. Analytical Modeling of Wood-Frame Shear Walls and Diaphragms

    … shear walls with improperly driven (overdriven)nails is determined along with a method to estimate strength reduction due to both the depth and the percentage of total nails overdriven.</p>

    byu Repository record for Analytical Modeling of Wood-Frame Shear Walls and Diaphragms (opens in a new tab)

  16. Slope Failure Remediation Design

    … removal of material, ‘H’ piles, and soils nails. The methods were analyzed using Slope 5.0. The proximity of the river and need for the road were the greatest constraints in considering a method of remediation. Benching created a stable slope, but the small area and steep slope would be …

    nodak Repository record for Slope Failure Remediation Design (opens in a new tab)

  17. Examination of the Lateral Resistance of Cross-Laminated Timber in Panel-Panel Connections

    … on non-proprietary connections, including nails, bolts and lag screws. The behavior of CLT full-scale wall panels is dependent upon the individual connection properties including the panel-panel connections between adjoining CLT panels within the wall. The purpose of this research is to …

    vt Repository record for Examination of the Lateral Resistance of Cross-Laminated Timber in Panel-Panel Connections (opens in a new tab)

  18. Ornamenting Fingernails and Roads: Beautification and the Embodiment of Authenticity in Post-War Eastern Sri Lanka

    … everyday exchanges from how women ornament their nails to how communities beautify their open—and sometimes contested—spaces. I draw on my ethnographic data from Eastern Sri Lanka and explore ‘color’ as negotiated through personal and public ornaments and notions of beauty with a material culture …

    penn Repository record for Ornamenting Fingernails and Roads: Beautification and the Embodiment of Authenticity in Post-War Eastern Sri Lanka (opens in a new tab)

  19. Reliability analyses for foundation and soil reinforcement applications

    … to identify the most influential parameter. Soil nails may be inserted into soils with bedding structures at different orientations. This thesis examines for the first time the influence of such cases on probabilistic margins of safety for a typical soil nail arrangement by assigning rotated …

    queens Repository record for Reliability analyses for foundation and soil reinforcement applications (opens in a new tab)

  20. Development of a magnetic targeting device applied to interlocking of distal intramedullary nail screw holes

    … fixation of long bones using intramedullary nails (IMN) has decreased incidence of non-union, allowed shorter hospitalization time, and earlier weight bearing for the patient compared to other fixation methods. Orthopedic surgeons have expressed that one of the most difficult parts of this …

    vt Repository record for Development of a magnetic targeting device applied to interlocking of distal intramedullary nail screw holes (opens in a new tab)

Page 1 of 4