Showing 1 to 20 of 74 for “"Static load"”.
-
Performance of short piled raft foundation system on peat soil under static load
… and replace, especially for foundation under static point load. This research was conducted to explore a proposed Short Piled Raft (SPR) foundation system, which is a combination of a pile foundation and raft foundation, with a pile length short enough. The objectives of this research were to …
-
Effects of topical fluoride prophylactic agents on the mechanical properties of orthodontic nickel-titanium closed coil springs
… orthodontic closed coil springs. Unloading force and rigidity were measured at 1, 4, 8, and 12 weeks, after springs were exposed to phosphate buffered saline (PBS), PBS combined with acidulated fluoride (PBS+APF) or sodium fluoride (PBS+NaF) with or without spring static loading. …
-
Statnamic Lateral Load Testing and Analysis of a Drilled Shaft in Liquefied Sand
Three progressively larger statnamic lateral load tests were performed on a 2.59 m diameter drilled shaft foundation after the surrounding soil was liquefied using down-hole explosive charges. An attempt to develop p-y curves from strain data along the pile was made. Due to low quality and lack of …
-
The fatigue performance assessment of corrosion damaged RC beams, patch repaired and externally strengthened using CFRP
… CFRP strengthened, were subjected to a monotonic load in order to establish the ultimate static load at failure for the RC beams. The ultimate static load at failure was then used to derive the maximum imposed cyclic fatigue loading that was applied. The remaining four RC beams were then subjected …
-
Dynamic ergonomic analysis and simulation of fastening operation
… and dynamic reaction force. Equivalent static load is calculated to combine the static and dynamic forces in fastening operation. Ergonomic analysis of individual risk factors is conducted and preventive actions are suggested.</p> <p>Tool vibrations were analyzed using the IS0-5349 …
-
Gerenciamento de potências usando um conversor modular em cascata para veículos elétricos com células a combustível
… results using a minimal topology prototype and static load show the practical application of the control.
-
Design and development of mechanical metatarsophalangeal joint for powered ankle-foot prostheses
… Heel) for a total of 4 models. We performed a static load Finite Element Analysis (FEA) using the Solidworks FEA Simulation Tool. The FEA was performed under the worst-case static load scenarios for the toe and body components of the prosthesis, standing on tiptoe with a dorsiflexion angle of …
-
The Correlation Between Biomechanical Loads and Psychophysical Ratings
… methodology, relate to physical (biomechanical) loads. A fundamental assumption of this method is that humans are capable of estimating biomechanical and physiological loads that are placed on the body. Based on this assumption, estimates that are obtained through the methodology are used as an …
-
Parallel dynamic load-balancing for adaptive distributive memory PDE solvers
… thesis is concerned with the issue of dynamic load-balancing in connection with the parallel adaptive solution of partial differential equations (PDEs). We are interested in parallel solutions based upon either finite element or finite volume schemes on unstructured grids and we assume that …
-
New Truck Loading Model For Rural Bridges In Saskatchewan
… existing information on estimating the critical load effects occurring on short span bridges, on low traffic roadways, and over specific reference periods makes it difficult to perform the bridge evaluations with an adequate degree of confidence. This study focuses on aspects of the estimation of …
-
Applicazione delle tecniche elettrosmotiche alla consolidazione dei fanghi di risulta dei processi mineralurgici
… the consolidation process, both under a static load (static consolidation) and a static load plus an electric field (combined consolidation). The research showed that the application of the electric gradient of 1V/cm reduces the consolidation time by about 80%. At the end of …
-
Ultra High Performance Fibre Reinforced Concrete Spandrel Cladding Panels in Façade Applications
… Reinforced Polymer (GFRP) reinforcing bars are load tested and compared to analytical calculations and the results of an elastic finite element analysis. Five panels are load tested, three subjected to static load testing, and two subjected to fatigue load testing. The deflection of the panels …
-
Dynamic load modeling in power system analysis
… induction machine modeling and polynomial static load modeling on the stability of electric power systems and to compare the results with those obtained using constant impedance or constant current load models. A least-squares curve fit algorithm is developed and used in modeling static and …
-
Nonlinear Finite Element Analysis of FRP Strengthened RC Beams under Static and Cyclic Loads
… behavior of FRP strengthened RC beams under static load. Very few finite element models for analysis of FRP-RC beam have been developed under cyclic load, and also the degradation of material properties of concrete, steel and FRP with number of cycles have been neglected in the existing few …
-
Comparison of the force and torque transfer for different cam profiles
This study presents static load and torque distribution measurements in groove cams for sinusoidal and cycloidal cam profiles. In this thesis, two different designs and apparatuses were developed and built for the static force and torque measurements in cam-follower systems. It was shown that for …
-
Frictional vibrations in structural polymers
… included: the time dependence of friction under static load, friction-normal load relationships, surface roughness, internal lubrication, friction-velocity relationships, and system stiffness. Four basic types of frictional behavior were observed - steady sliding, a single stick followed by …
-
Optimization of a roll over protective structure (ROPS) using nonlinear finite element analysis
… and deflection results against the SAE J2I94 Static Load Standard. (Abstract shortened by UMI.).
-
Network and Load Modeling for Power System Dynamic Analysis
… thesis involves the development of network and load models for power system analysis. Traditional power system models consist of detailed generator models and simple network and load models. In the past this has been acceptable as these models captured observed phenomena. These models do not …
-
Investigation of Steel Joist Supported Wood Floor Systems
… perpendicular and parallel to the floor joists, static concentrated load at midspan, and testing to determine subjective evaluation. Five acceptability criteria were investigated: Swedish Building Technology Design Guide, Australian Standard Domestic Metal Framing Code, Canadian Timber Floor …
Page 1 of 4