Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"Hidden Failures"”.

  1. Hidden Failures in Shipboard Electrical Integrated Propulsion Plants

    … this work. A model was developed for simulating hidden failures on shipboard integrated propulsion plants, IPP. The model was then used to evaluate the segregation of the IPP high voltage, HV, buses in a similar fashion as a shipboard firemain. The HV buses were segregated when loss of propulsion …

    vt Repository record for Hidden Failures in Shipboard Electrical Integrated Propulsion Plants (opens in a new tab)

  2. Analysis of power system disturbances due to relay hidden failures

    … linkage between power system disturbances and failures in relaying systems. The annual disturbance reports prepared by the North American Electric Reliability Council were examined. It has been found that relaying system failures plays very important role in power system cascading outages. The …

    vt Repository record for Analysis of power system disturbances due to relay hidden failures (opens in a new tab)

  3. Hidden Failures in Protection Systems and its Impact on Power System Wide-area Disturbances

    This document explores Hidden Failures in protection systems, which have been identified as key contributors in the degradation of Power System wide-area disturbances. The Hidden Failure Modes in which the protection systems may fail to operate correctly and their consequences are identified in a …

    vt Repository record for Hidden Failures in Protection Systems and its Impact on Power System Wide-area Disturbances (opens in a new tab)

  4. A Methodology to Assess and Rank the Effects of Hidden Failures in Protection Schemes based on Regions of Vulnerability and Index of Severity

    … of the disturbances. This research defined hidden failures of protection schemes and showed that these kinds of failures have contributed in the degradation of 70-80 percent of the wide-area disturbances. During a wide-area disturbance analysis, it was found that hidden failures in …

    vt Repository record for A Methodology to Assess and Rank the Effects of Hidden Failures in Protection Schemes based on Regions of Vulnerability and Index of Severity (opens in a new tab)

  5. Hidden Failure in Protective Relays: Supervision and Control

    … the relay system to prevent trips due to hidden failures. During wide area network disturbances, it adapts the relay system to increase security of the power system. The RSS works passively in the sense that it waits for events to occur in the existing relay system before taking any …

    vt Repository record for Hidden Failure in Protective Relays: Supervision and Control (opens in a new tab)

  6. Methodology for a Security-Dependability Adaptive Protection Scheme based on Data Mining

    … scheme. It is argued that the likelihood of hidden failures and potential cascading events can be significantly reduced by adjusting the security/dependability balance of protection systems to better suit prevailing system conditions. The proposed methodology is based on Wide Area …

    vt Repository record for Methodology for a Security-Dependability Adaptive Protection Scheme based on Data Mining (opens in a new tab)

  7. Cascading Events in the Aftermath of a Targeted Physical Attack on the Power Grid

    … of the target set size k. The consideration of hidden failures in the protective relays has revealed that the outage of certain lines/buses in the course of cascading events can save the power grid from a system collapse. Finally, a comparison with the DC steady state analysis of cascading …

    vt Repository record for Cascading Events in the Aftermath of a Targeted Physical Attack on the Power Grid (opens in a new tab)

  8. Risk Assessment of Power System Catastrophic Failures and Hidden Failure Monitoring & Control System

    … in a power system, the risks of catastrophic failures caused by hidden failures in the hardware or software components of the protection system. The disturbance propagation mechanism is revealed by the analysis of the 1977 New York Blackout. The step-by-step process of estimating the relay …

    vt Repository record for Risk Assessment of Power System Catastrophic Failures and Hidden Failure Monitoring & Control System (opens in a new tab)

  9. Enabling Communication and Networking Technologies for Smart Grid

    … Council (NERC) has concluded that the hidden failure induced tripping of distance relays is responsible for 70% of the U.S. blackouts. As a part of this dissertation, agent based distance relaying protection scheme is proposed to improve the robustness of distance relays to hidden

    vt Repository record for Enabling Communication and Networking Technologies for Smart Grid (opens in a new tab)

  10. Critical Substation Risk Assessment and Mitigation

    Substations are joints in the power system that represent nodes that are vital to stable and reliable operation of the power system. They contrast the rest of the power system in that they are a dense combination of critical components causing all of them to be simultaneously vulnerable to one …

    vt Repository record for Critical Substation Risk Assessment and Mitigation (opens in a new tab)