Back to search

Central Florida

Water Quality Variations During Nitrification In Drinking Water Distribution Systems

Abstract

dc:description.abstract

This thesis documents the relationship among the major water quality parameters during a nitrification episode. Nitrification unexpectedly occurred in a chloraminated pilot drinking water distribution system practicing with a 4.0 mg/L as Cl2 residual dosed at 4.5:1 Cl2:NH3-N. Surface, ground and sea water were treated and disinfected with monochloramines to produce finished water quality similar to regional utility water quality. PVC, galvanized, unlined cast iron and lined iron pipes were harvested from regional distribution systems and used to build eighteen pilot distribution systems (PDSs). The PDSs were operated at a 5-day hydraulic residence time (HRT) and ambient temperatures. As seasonal temperatures increased the rate of monochloramine dissipation increased until effluent PDS residuals were zero. PDSs effluent water quality parameters chloramines residual, dissolved oxygen, heterotrophic plate counts (HPCs), pH, alkalinity, and nitrogen species were monitored and found to vary as expected by stoichiometry associated with theoretical biological reactions excepting alkalinity. Nitrification was confirmed in the PDSs. The occurrence in the PDSs was not isolated to any particular source water. Ammonia for nitrification came from degraded chloramines, which was common among all finished waters. Consistent with nitrification trends of dissolved oxygen consumption, ammonia consumption, nitrite and nitrate production were clearly observed in the PDSs bulk water quality profiles. Trends of pH and alkalinity were less apparent. To control nitrification: residual was increased to 4.5 mg/L as Cl2 at 5:1 Cl2:NH3-N dosing ratio, and the HRT was reduced from 5 to 2 days. Elimination of the nitrification episode was achieved after a 1 week free chlorine burn.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Webb, David W
Contributors dc:contributor
  • Taylor, James S.

Subjects

dc:subject × 7

Rights

Language dc:language
English

Identifiers

dc:identifier.*
Identifier
CFE0000063
OAI identifier oai:identifier
oai:stars.library.ucf.edu:etd-1015

Chain of custody

source
Harvested from
Central Florida
Base URL
stars.library.ucf.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Webb, David W. Water Quality Variations During Nitrification In Drinking Water Distribution Systems. 2004. https://stars.library.ucf.edu/etd/16