Experimental study of thermosiphon performance

Abstract

dc:description.abstract

A model single phase loop thermosiphon was designed and built such that velocity profiles and heat transfer rates could be studied by obtaining temperature data, along with a detailed set of non-intrusive Laser Doppler Velocimetry measurements. The quantities measured were the instantaneous velocity profiles for the water flow. These velocities were then reduced into sets of mean and root mean square velocities, for different angles of tilt of the experimental setup. Nominal heating and cooling rates were held constant.;The single phase thermosiphon consisted of an aluminum flow loop, fitted with a test section made of Plexiglas, that was rectangular in cross section. The entire pipe loop was filled with distilled water for this set of experiments. Flow was generated by thermoelectric coolers fixed on both sides of the top leg and thermoelectric heaters fixed on both sides of the bottom leg of the thermosiphon. The flow direction was reversed by changing the angle of tilt of the experimental setup. The data were taken across the 1.5 inch and 0.75 inch dimensions of the test section at both the center and at the right end of the wall as tilt angle was varied from 3.6 degrees clockwise to 4.2 degrees counter clockwise.;The predicted velocities from a one dimensional flow model were 3--4 times bigger than the observed mean velocities. Average heating rate was 70 Watts, while measured average cooling rate was 27 Watts. RMS velocities were typically 10--20% of the mean velocities. It was found that the mean velocity profiles across the 1.5 inch dimension of the flow area were consistently higher near the back wall and lower near the front wall of the test section.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Mechanical and Aerospace Engineering
Year dc:date.available
2002

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sivanagere, Sumeeth S.
Contributors dc:contributor
  • John M. Kuhlman.

Subjects

dc:subject × 2

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:researchrepository.wvu.edu:etd-2265

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Sivanagere, Sumeeth S.. Experimental study of thermosiphon performance. Thesis thesis, 2002. https://doi.org/10.33915/etd.1262