Massachusetts Institute of Technology and Woods Hole Oceanographic Institution
Verification of numerical models for hydrothermal plume water through field measurements at TAG
Abstract
dc:description.abstractHydrothermal vents discharge superheated, mineral rich water into our oceans, thereby providing a habitat for exotic chemosynthetic biological communities. Hydrothermal fluids are convected upwards until they cool and reach density equilibrium, at which point they advect laterally with the current. The neutrally buoyant plume layer can have length scales on the order of several kilometers, and it therefore provides the best means to detect the presence of vent fields on the seafloor, which typically have length scales on the order of a few meters. This thesis uses field measurements of the velocity, temperature and particulate anomalies associated with the TAG hydrothermal plume to demonstrate that tidal currents exert a strong impact on the plume shape, and to provide new constraints on the thermal power of the TAG hydrothermal system. The results show that the power output of the TAG system is on the order of 6000 MW, which is up to two orders of magnitude greater than previous estimates, and that there is considerably more entrainment than had previously been assumed.
Degree
thesis:*- Grantor dc:publisher
- Massachusetts Institute of Technology and Woods Hole Oceanographic Institution
- Year dc:date.issued
- 2005
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Wichers, Sacha
Subjects
dc:subject × 3Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- OAI identifier oai:identifier
- oai:darchive.mblwhoilibrary.org:1912/1640