{"id":{"repo_id":"wku-diss","oai_identifier":"oai:digitalcommons.wku.edu:theses-2211"},"canonical_url":"https://search.dev.ndltd.org/etd/wku-diss/oai:digitalcommons.wku.edu:theses-2211","repository":{"repo_id":"wku-diss","name":"Western Kentucky University","base_url":"https://digitalcommons.wku.edu/do/oai/"},"display":{"title":"Determination of Repetitive Jumping Intensity Relative to Measured VO<sub>2max</sub>","abstract":"<p>To regular exercise and a healthy diet, the American Heart Association (AHA) strongly recommends rope jumping, and according to previous studies, rope jumping is considered a very strenuous exercise. Therefore the purpose of this study was to determine the steady state metabolic cost of repetitive jumping on the Digi-Jump machine, and to determine if exercise on this device is more or less strenuous than similar exercise with a jump rope. We also evaluated relative intensity of this type of exercise, based on each person’s VO<sub>2max</sub> as measured on a treadmill. Twenty – seven subjects completed two trials, one jumping trial at a rate of 120 jumps per minute (JPM) with the jumping height set at .5 inch for 5 min, and one graded exercise test (GXT) using the Bruce protocol. Oxygen uptake (VO<sub>2</sub>), heart rate (HR), respiratory exchange ratio (RER), and rating perceived exertion (RPE) were measured each minute during each trial. Results of this study indicated that steady state VO<sub>2</sub> during the 5 min jump test was reached at the 3rd min (p < .05), therefore we equated all other variables (HR, RE, RPE) steady state to be from 3rd min. Average jumping steady state VO<sub>2</sub> was 31.1 ± 5.5 ml/kg/min, while average VO<sub>2max</sub> was 56.4 ± 12 ml/kg/min, thus steady state VO<sub>2</sub> during jumping trial was 57.1% of VO<sub>2max</sub>. Average jumping steady state HR was 149. 2 ± 20.1 bpm, while mean GXT HR was 184.7 ± 9.9 bpm, thus steady state HR during jumping trial was 80.9% of their maximal HR obtained during GXT. Average jumping steady state RER was .99 ± .6,while average GXT RER was 1.15 ± .07, thus steady state RER during jumping trial was 86%, and average jumping steady state RPE was 13.5 ± 1.5, while average GXT RPE was 17.9 ± 1, thus steady state RPE during jumping trial was 75.2%. These data indicate that jumping is a strenuous activity, even if the trial is done on Digi – Jump machine without rope.</p>","abstract_html":"&lt;p&gt;To regular exercise and a healthy diet, the American Heart Association (AHA) strongly recommends rope jumping, and according to previous studies, rope jumping is considered a very strenuous exercise. Therefore the purpose of this study was to determine the steady state metabolic cost of repetitive jumping on the Digi-Jump machine, and to determine if exercise on this device is more or less strenuous than similar exercise with a jump rope. We also evaluated relative intensity of this type of exercise, based on each person’s VO&lt;sub&gt;2max&lt;/sub&gt; as measured on a treadmill. Twenty – seven subjects completed two trials, one jumping trial at a rate of 120 jumps per minute (JPM) with the jumping height set at .5 inch for 5 min, and one graded exercise test (GXT) using the Bruce protocol. Oxygen uptake (VO&lt;sub&gt;2&lt;/sub&gt;), heart rate (HR), respiratory exchange ratio (RER), and rating perceived exertion (RPE) were measured each minute during each trial. Results of this study indicated that steady state VO&lt;sub&gt;2&lt;/sub&gt; during the 5 min jump test was reached at the 3rd min (p &lt; .05), therefore we equated all other variables (HR, RE, RPE) steady state to be from 3rd min. Average jumping steady state VO&lt;sub&gt;2&lt;/sub&gt; was 31.1 ± 5.5 ml/kg/min, while average VO&lt;sub&gt;2max&lt;/sub&gt; was 56.4 ± 12 ml/kg/min, thus steady state VO&lt;sub&gt;2&lt;/sub&gt; during jumping trial was 57.1% of VO&lt;sub&gt;2max&lt;/sub&gt;. Average jumping steady state HR was 149. 2 ± 20.1 bpm, while mean GXT HR was 184.7 ± 9.9 bpm, thus steady state HR during jumping trial was 80.9% of their maximal HR obtained during GXT. Average jumping steady state RER was .99 ± .6,while average GXT RER was 1.15 ± .07, thus steady state RER during jumping trial was 86%, and average jumping steady state RPE was 13.5 ± 1.5, while average GXT RPE was 17.9 ± 1, thus steady state RPE during jumping trial was 75.2%. These data indicate that jumping is a strenuous activity, even if the trial is done on Digi – Jump machine without rope.&lt;/p&gt;","abstract_has_math":false,"creators":["Igaune, Laura"],"institution":null,"degree_name":"Master of Science","degree_level":null,"degree_discipline":"Department of Kinesiology, Recreation and Sport","degree_department":null,"school":null,"contributors":["Dr. Scott Lyons (Director), Dr. Mark Schafer, Dr. Scott Arnett, Dr. Gina Evans"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-12-01T08:00:00Z","date_published":"2012-12-01T08:00:00Z","updated_at":"2026-07-24T06:08:16Z","subjects":["cardiovascular exercise","metabolism","exercise science","Kinesiology","Psychology of Movement","Sports Studies"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.wku.edu/theses/1208","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Scott Lyons (Director), Dr. Mark Schafer, Dr. Scott Arnett, Dr. Gina Evans"]},{"key":"dc:creator","label":"Author","values":["Igaune, Laura"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Kinesiology, Recreation and Sport"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["cardiovascular exercise","metabolism","exercise science","Kinesiology","Psychology of Movement","Sports Studies"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.wku.edu/theses/1208"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>To regular exercise and a healthy diet, the American Heart Association (AHA) strongly recommends rope jumping, and according to previous studies, rope jumping is considered a very strenuous exercise. Therefore the purpose of this study was to determine the steady state metabolic cost of repetitive jumping on the Digi-Jump machine, and to determine if exercise on this device is more or less strenuous than similar exercise with a jump rope. We also evaluated relative intensity of this type of exercise, based on each person’s VO<sub>2max</sub> as measured on a treadmill. Twenty – seven subjects completed two trials, one jumping trial at a rate of 120 jumps per minute (JPM) with the jumping height set at .5 inch for 5 min, and one graded exercise test (GXT) using the Bruce protocol. Oxygen uptake (VO<sub>2</sub>), heart rate (HR), respiratory exchange ratio (RER), and rating perceived exertion (RPE) were measured each minute during each trial. Results of this study indicated that steady state VO<sub>2</sub> during the 5 min jump test was reached at the 3rd min (p < .05), therefore we equated all other variables (HR, RE, RPE) steady state to be from 3rd min. Average jumping steady state VO<sub>2</sub> was 31.1 ± 5.5 ml/kg/min, while average VO<sub>2max</sub> was 56.4 ± 12 ml/kg/min, thus steady state VO<sub>2</sub> during jumping trial was 57.1% of VO<sub>2max</sub>. Average jumping steady state HR was 149. 2 ± 20.1 bpm, while mean GXT HR was 184.7 ± 9.9 bpm, thus steady state HR during jumping trial was 80.9% of their maximal HR obtained during GXT. Average jumping steady state RER was .99 ± .6,while average GXT RER was 1.15 ± .07, thus steady state RER during jumping trial was 86%, and average jumping steady state RPE was 13.5 ± 1.5, while average GXT RPE was 17.9 ± 1, thus steady state RPE during jumping trial was 75.2%. These data indicate that jumping is a strenuous activity, even if the trial is done on Digi – Jump machine without rope.</p>"]},{"key":"dc:title","label":"Title","values":["Determination of Repetitive Jumping Intensity Relative to Measured VO<sub>2max</sub>"]}]}],"canonical_facts":{"dc:contributor":["Dr. Scott Lyons (Director), Dr. Mark Schafer, Dr. Scott Arnett, Dr. Gina Evans"],"dc:creator":["Igaune, Laura"],"dc:description.abstract":["<p>To regular exercise and a healthy diet, the American Heart Association (AHA) strongly recommends rope jumping, and according to previous studies, rope jumping is considered a very strenuous exercise. Therefore the purpose of this study was to determine the steady state metabolic cost of repetitive jumping on the Digi-Jump machine, and to determine if exercise on this device is more or less strenuous than similar exercise with a jump rope. We also evaluated relative intensity of this type of exercise, based on each person’s VO<sub>2max</sub> as measured on a treadmill. Twenty – seven subjects completed two trials, one jumping trial at a rate of 120 jumps per minute (JPM) with the jumping height set at .5 inch for 5 min, and one graded exercise test (GXT) using the Bruce protocol. Oxygen uptake (VO<sub>2</sub>), heart rate (HR), respiratory exchange ratio (RER), and rating perceived exertion (RPE) were measured each minute during each trial. Results of this study indicated that steady state VO<sub>2</sub> during the 5 min jump test was reached at the 3rd min (p < .05), therefore we equated all other variables (HR, RE, RPE) steady state to be from 3rd min. Average jumping steady state VO<sub>2</sub> was 31.1 ± 5.5 ml/kg/min, while average VO<sub>2max</sub> was 56.4 ± 12 ml/kg/min, thus steady state VO<sub>2</sub> during jumping trial was 57.1% of VO<sub>2max</sub>. Average jumping steady state HR was 149. 2 ± 20.1 bpm, while mean GXT HR was 184.7 ± 9.9 bpm, thus steady state HR during jumping trial was 80.9% of their maximal HR obtained during GXT. Average jumping steady state RER was .99 ± .6,while average GXT RER was 1.15 ± .07, thus steady state RER during jumping trial was 86%, and average jumping steady state RPE was 13.5 ± 1.5, while average GXT RPE was 17.9 ± 1, thus steady state RPE during jumping trial was 75.2%. These data indicate that jumping is a strenuous activity, even if the trial is done on Digi – Jump machine without rope.</p>"],"dc:identifier":["https://digitalcommons.wku.edu/theses/1208"],"dc:subject":["cardiovascular exercise","metabolism","exercise science","Kinesiology","Psychology of Movement","Sports Studies"],"dc:title":["Determination of Repetitive Jumping Intensity Relative to Measured VO<sub>2max</sub>"],"dc:type":["Thesis"],"thesis:degree_discipline":["Department of Kinesiology, Recreation and Sport"],"thesis:degree_name":["Master of Science"]},"updated_at":"2026-07-24T06:08:16Z"}