Back to results

Wake Forest University

AN ANALYSIS OF THE BUCKLING BEHAVIOR OF SPINAL ANESTHESIA NEEDLES

Abstract

dc:description.abstract

The use of large gauge (G) spinal anesthesia needles can increase complications due to buckling. The purpose of this study was to, first, create a model to repeatably simulate and quantify the behavior of spinal needles in buckling and, second, quantify the buckling behavior of spinal anesthesia needles with respect to the relative contribution of needle gauge, brand, tissue depth (i.e. patient size) and the use of a stylet. A repeatable spinal anesthesia procedure and buckling complication was simulated using a custom test fixture designed to match the boundary conditions of needle insertion as performed by an anesthesiologist and a uniaxial servohydraulic material testing machine (MTS, Eden Prairie MN). Buckling tests were performed with 22G, 24G, 25G and 27G BD Whitacre, Havel Pajunk, Gertie Marx and B.Braun Pencan needles in a ballistics gelatin tissue surrogate. In analyzing axial force changes, critical buckling load results were 27.65±0.918N. Due to the large force magnitude that can be withstood by spinal needles in compression, it can be concluded that the problem of needle buckling is not a consequence of needle fragility. The differential between the resultant insertion force and the critical buckling force is more important to the detection of needle buckling than the critical buckling force alone. In clinic, a very small difference in these two forces could feel like expected resistance increase as the needle is further inserted into the multiple tissue layers. Comparison of the differential between the resultant insertion force and the critical buckling force, termed ∆FIC, should be considered when choosing a needle to best detect and prevent a buckling complication. Needle gauge was the most significant factor affecting ∆FIC results, followed by tissue depth, needle brand and use of a stylet. The results of this study can be used to determine which needle type is best for each patient. We hope that the information obtained from this study will help us obtain our long-term goal of improving spinal anesthesia procedural safety.

Degree

thesis:*
Grantor dc:publisher
Wake Forest University
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hulburt, Tessa

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10339/93045
OAI identifier oai:identifier
oai:wakespace.lib.wfu.edu:10339/93045

Chain of custody

source
Harvested from
Wake Forest University
Base URL
wakespace.lib.wfu.edu/oai/request
Last updated
2026-07-27
Source record
OAI-PMH GetRecord
related terms
citation

Hulburt, Tessa. AN ANALYSIS OF THE BUCKLING BEHAVIOR OF SPINAL ANESTHESIA NEEDLES. Wake Forest University, 2018. http://hdl.handle.net/10339/93045