Characterization and chemical speciation modelling of saline effluents at Sasol Synthetic Fuels Complex-Secunda and Tukuta power station

Abstract

dc:description.abstract

The study shows conclusively that brine composition and concentration is highly variable at these South African power utilities and processes such as RO, contact with ash and CO2 ingress can have an impact upon the overall brine quality. Aq.QA was found to be a more accurate tool for classifying waters according to dominant ions than Stiff diagrams but Stiff diagrams still have the superior advantage of being a mapping tool to easily identify samples of similar composition as well as quickly identify what has been added or what has been removed from a water stream. Chemical speciation could identify effluent streams where CO2 dissolution had taken place.