{"id":{"repo_id":"wayne-thes","oai_identifier":"oai:digitalcommons.wayne.edu:oa_dissertations-1987"},"canonical_url":"https://search.dev.ndltd.org/etd/wayne-thes/oai:digitalcommons.wayne.edu:oa_dissertations-1987","repository":{"repo_id":"wayne-thes","name":"Wayne State University","base_url":"https://digitalcommons.wayne.edu/do/oai/"},"display":{"title":"High-Performance Accelerometer Based On Asymmetric Gapped Cantilevers For Physiological Acoustic Sensing","abstract":"<p>Continuous or mobile monitoring of physiological sounds is expected to play important role in the emerging mobile healthcare field. Because of the miniature size, low cost, and easy installation, accelerometer is an excellent choice for continuous physiological acoustic signal monitoring. However, in order to capture the detailed information in the physiological signals for clinical diagnostic purpose, there are more demanding requirements on the sensitivity/noise performance of accelerometers. In this thesis, a unique piezoelectric accelerometer based on the asymmetric gapped cantilever which exhibits significantly improved sensitivity is extensively studied. A meso-scale prototype is developed for capturing the high quality cardio and respiratory sounds on healthy people as well as on heart failure patients. A cascaded gapped cantilever based accelerometer is also explored for low frequency vibration sensing applications such as ballistocardiogram monitoring. Finally, to address the power issues of wireless sensors such as wireless wearable health monitors, a wide band vibration energy harvester based on a folded gapped cantilever is developed and demonstrated on a ceiling air condition unit.</p>","abstract_html":"&lt;p&gt;Continuous or mobile monitoring of physiological sounds is expected to play important role in the emerging mobile healthcare field. Because of the miniature size, low cost, and easy installation, accelerometer is an excellent choice for continuous physiological acoustic signal monitoring. However, in order to capture the detailed information in the physiological signals for clinical diagnostic purpose, there are more demanding requirements on the sensitivity/noise performance of accelerometers. In this thesis, a unique piezoelectric accelerometer based on the asymmetric gapped cantilever which exhibits significantly improved sensitivity is extensively studied. A meso-scale prototype is developed for capturing the high quality cardio and respiratory sounds on healthy people as well as on heart failure patients. A cascaded gapped cantilever based accelerometer is also explored for low frequency vibration sensing applications such as ballistocardiogram monitoring. Finally, to address the power issues of wireless sensors such as wireless wearable health monitors, a wide band vibration energy harvester based on a folded gapped cantilever is developed and demonstrated on a ceiling air condition unit.&lt;/p&gt;","abstract_has_math":false,"creators":["Hu, Yating"],"institution":null,"degree_name":"Ph.D.","degree_level":"Open Access Dissertation","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Yong Xu"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-01-01T08:00:00Z","date_published":"2014-01-01T08:00:00Z","updated_at":"2026-07-24T05:59:39Z","subjects":["accelerometer","acoustic","heart sound","physiological sensing","vibration energy harvesting","Biomedical Engineering and Bioengineering","Electrical and Computer Engineering","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.wayne.edu/oa_dissertations/988","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yong Xu"]},{"key":"dc:creator","label":"Author","values":["Hu, Yating"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2016-01-14T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Open Access Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["accelerometer","acoustic","heart sound","physiological sensing","vibration energy harvesting","Biomedical Engineering and Bioengineering","Electrical and Computer Engineering","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.wayne.edu/oa_dissertations/988"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Continuous or mobile monitoring of physiological sounds is expected to play important role in the emerging mobile healthcare field. Because of the miniature size, low cost, and easy installation, accelerometer is an excellent choice for continuous physiological acoustic signal monitoring. However, in order to capture the detailed information in the physiological signals for clinical diagnostic purpose, there are more demanding requirements on the sensitivity/noise performance of accelerometers. In this thesis, a unique piezoelectric accelerometer based on the asymmetric gapped cantilever which exhibits significantly improved sensitivity is extensively studied. A meso-scale prototype is developed for capturing the high quality cardio and respiratory sounds on healthy people as well as on heart failure patients. A cascaded gapped cantilever based accelerometer is also explored for low frequency vibration sensing applications such as ballistocardiogram monitoring. Finally, to address the power issues of wireless sensors such as wireless wearable health monitors, a wide band vibration energy harvester based on a folded gapped cantilever is developed and demonstrated on a ceiling air condition unit.</p>"]},{"key":"dc:title","label":"Title","values":["High-Performance Accelerometer Based On Asymmetric Gapped Cantilevers For Physiological Acoustic Sensing"]}]}],"canonical_facts":{"dc:contributor":["Yong Xu"],"dc:creator":["Hu, Yating"],"dc:date.available":["2016-01-14T08:00:00Z"],"dc:description.abstract":["<p>Continuous or mobile monitoring of physiological sounds is expected to play important role in the emerging mobile healthcare field. Because of the miniature size, low cost, and easy installation, accelerometer is an excellent choice for continuous physiological acoustic signal monitoring. However, in order to capture the detailed information in the physiological signals for clinical diagnostic purpose, there are more demanding requirements on the sensitivity/noise performance of accelerometers. In this thesis, a unique piezoelectric accelerometer based on the asymmetric gapped cantilever which exhibits significantly improved sensitivity is extensively studied. A meso-scale prototype is developed for capturing the high quality cardio and respiratory sounds on healthy people as well as on heart failure patients. A cascaded gapped cantilever based accelerometer is also explored for low frequency vibration sensing applications such as ballistocardiogram monitoring. Finally, to address the power issues of wireless sensors such as wireless wearable health monitors, a wide band vibration energy harvester based on a folded gapped cantilever is developed and demonstrated on a ceiling air condition unit.</p>"],"dc:identifier":["https://digitalcommons.wayne.edu/oa_dissertations/988"],"dc:subject":["accelerometer","acoustic","heart sound","physiological sensing","vibration energy harvesting","Biomedical Engineering and Bioengineering","Electrical and Computer Engineering","Mechanical Engineering"],"dc:title":["High-Performance Accelerometer Based On Asymmetric Gapped Cantilevers For Physiological Acoustic Sensing"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Open Access Dissertation"],"thesis:degree_name":["Ph.D."]},"updated_at":"2026-07-24T05:59:39Z"}