Back to results

Wayne State University

Modeling Of Mouse Eye And Errors In Ocular Parameters Affecting Refractive State

Abstract

dc:description.abstract

<p>ABSTRACT</p> <p>MODELING OF MOUSE EYE AND ERRORS IN OCULAR PARAMETERS AFFECTING REFRACTIVE STATE</p> <p>by</p> <p>GURINDER BAWA</p> <p>September 2013</p> <p>Advisor: Dr. Ivan Avrutsky</p> <p>Major: Electrical Engineering</p> <p>Degree: Doctor of Philosophy</p> <p>Rodents eye are particularly used to study refractive error state of an eye and development of refractive eye. Genetic organization of rodents is similar to that of humans, which makes them interesting candidates to be researched upon. From rodents family mice models are encouraged over rats because of availability of genetically engineered models. Despite of extensive work that has been performed on mice and rat models, still no one is able to quantify an optical model, due to variability in the reported ocular parameters. </p> <p>In this Dissertation, we have extracted ocular parameters and generated schematics of eye from the raw data from School of Medicine, Detroit. In order to see how the rays would travel through an eye and the defects associated with an eye; ray tracing has been performed using ocular parameters. Finally we have systematically evaluated the contribution of various ocular parameters, such as radii of curvature of ocular surfaces, thicknesses of ocular components, and refractive indices of ocular refractive media, using variational analysis and a computational model of the rodent eye. </p> <p>Variational analysis revealed that variation in all the ocular parameters does affect the refractive status of the eye, but depending upon the magnitude of the impact those parameters are listed as critical or non critical. Variation in the depth of the vitreous chamber, thickness of the lens, radius of the anterior surface of the cornea, radius of the anterior surface of the lens, as well as refractive indices for the lens and vitreous, appears to have the largest impact on the refractive error and thus are categorized as critical ocular parameters. The radii of the posterior surfaces of the cornea and lens have much smaller contributions to the refractive state, while the radii of the anterior and posterior surfaces of the retina have no effect on the refractive error. These data provide the framework for further refinement of the optical models of the rat and mouse eye and suggest that extra efforts should be directed towards increasing the linear resolution of the rodent eye biometry and obtaining more accurate data for the refractive indices of the lens and vitreous.</p>

Degree

thesis:*
Name thesis:degree_name
Ph.D.
Level thesis:degree_level
Open Access Dissertation
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Year dc:date.available
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bawa, Gurinder
Contributors dc:contributor
  • Ivan Avrutsky

Subjects

dc:subject × 2

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:digitalcommons.wayne.edu:oa_dissertations-1748

Chain of custody

source
Harvested from
Wayne State University
Base URL
digitalcommons.wayne.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Bawa, Gurinder. Modeling Of Mouse Eye And Errors In Ocular Parameters Affecting Refractive State. Open Access Dissertation thesis, 2013. https://digitalcommons.wayne.edu/oa_dissertations/749