{"id":{"repo_id":"washington","oai_identifier":"oai:digital.lib.washington.edu:1773/46736"},"canonical_url":"https://search.dev.ndltd.org/etd/washington/oai:digital.lib.washington.edu:1773/46736","repository":{"repo_id":"washington","name":"University of Washington","base_url":"https://digital.lib.washington.edu/server/oai/request"},"display":{"title":"Resonating Fluidic Circuits: A Novel Technology to Create a Portable Blood Viscoelasticity Measuring Device","abstract":"The prehospital detection of coagulopathy has been identified as an important goal for the future of emergency medicine and trauma care. However, no clinically accepted devices that can diagnose coagulopathy by measuring blood clot viscoelasticity are portable, meaning that coagulopathy can only be diagnosed inside a well-resourced hospital. Resonating fluidic circuits are a promising technology to address this clinical need. In addition to being small enough to fit into a pocket, they are inexpensive to produce, and it has been suggested that they can be used to measure viscoelasticity. Previous research undertakings on fluidic circuits have not fully explored the potential of the technology to be applied to this clinical need. In this work, the scientific understanding of fluidic circuits is expanded, a fluidic circuit design is created for optimal viscoelastic measurement of blood clots, a portable, inexpensive, and efficient method of electrically instrumenting fluidic circuits is developed, and finally, the system is evaluated for its ability to specifically measure clot viscoelasticity relative to an existing device.","abstract_html":"The prehospital detection of coagulopathy has been identified as an important goal for the future of emergency medicine and trauma care. However, no clinically accepted devices that can diagnose coagulopathy by measuring blood clot viscoelasticity are portable, meaning that coagulopathy can only be diagnosed inside a well-resourced hospital. Resonating fluidic circuits are a promising technology to address this clinical need. In addition to being small enough to fit into a pocket, they are inexpensive to produce, and it has been suggested that they can be used to measure viscoelasticity. Previous research undertakings on fluidic circuits have not fully explored the potential of the technology to be applied to this clinical need. In this work, the scientific understanding of fluidic circuits is expanded, a fluidic circuit design is created for optimal viscoelastic measurement of blood clots, a portable, inexpensive, and efficient method of electrically instrumenting fluidic circuits is developed, and finally, the system is evaluated for its ability to specifically measure clot viscoelasticity relative to an existing device.","abstract_has_math":false,"creators":["Eckhoff, Colin Christian"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Lutz, Barry"],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-03-19","date_published":"2021-03-19","updated_at":"2026-07-24T05:58:12Z","subjects":["Engineering"],"languages":["en_US"],"rights":["none"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1773/46736","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lutz, Barry"]},{"key":"dc:creator","label":"Author","values":["Eckhoff, Colin Christian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-03-19T22:52:32Z"]},{"key":"dc:date.issued","label":"Date","values":["2021-03-19"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["none"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["Eckhoff_washington_0250O_22469.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1773/46736"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master's)--University of Washington, 2020"]},{"key":"dc:description.abstract","label":"Abstract","values":["The prehospital detection of coagulopathy has been identified as an important goal for the future of emergency medicine and trauma care. However, no clinically accepted devices that can diagnose coagulopathy by measuring blood clot viscoelasticity are portable, meaning that coagulopathy can only be diagnosed inside a well-resourced hospital. Resonating fluidic circuits are a promising technology to address this clinical need. In addition to being small enough to fit into a pocket, they are inexpensive to produce, and it has been suggested that they can be used to measure viscoelasticity. Previous research undertakings on fluidic circuits have not fully explored the potential of the technology to be applied to this clinical need. In this work, the scientific understanding of fluidic circuits is expanded, a fluidic circuit design is created for optimal viscoelastic measurement of blood clots, a portable, inexpensive, and efficient method of electrically instrumenting fluidic circuits is developed, and finally, the system is evaluated for its ability to specifically measure clot viscoelasticity relative to an existing device."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Resonating Fluidic Circuits: A Novel Technology to Create a Portable Blood Viscoelasticity Measuring Device"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lutz, Barry"],"dc:creator":["Eckhoff, Colin Christian"],"dc:date.accessioned":["2021-03-19T22:52:32Z"],"dc:date.issued":["2021-03-19"],"dc:description":["Thesis (Master's)--University of Washington, 2020"],"dc:description.abstract":["The prehospital detection of coagulopathy has been identified as an important goal for the future of emergency medicine and trauma care. However, no clinically accepted devices that can diagnose coagulopathy by measuring blood clot viscoelasticity are portable, meaning that coagulopathy can only be diagnosed inside a well-resourced hospital. Resonating fluidic circuits are a promising technology to address this clinical need. In addition to being small enough to fit into a pocket, they are inexpensive to produce, and it has been suggested that they can be used to measure viscoelasticity. Previous research undertakings on fluidic circuits have not fully explored the potential of the technology to be applied to this clinical need. In this work, the scientific understanding of fluidic circuits is expanded, a fluidic circuit design is created for optimal viscoelastic measurement of blood clots, a portable, inexpensive, and efficient method of electrically instrumenting fluidic circuits is developed, and finally, the system is evaluated for its ability to specifically measure clot viscoelasticity relative to an existing device."],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["Eckhoff_washington_0250O_22469.pdf"],"dc:identifier.uri":["http://hdl.handle.net/1773/46736"],"dc:language.iso":["en_US"],"dc:rights":["none"],"dc:subject":["Engineering"],"dc:title":["Resonating Fluidic Circuits: A Novel Technology to Create a Portable Blood Viscoelasticity Measuring Device"],"dc:type":["Thesis"]},"updated_at":"2026-07-24T05:58:12Z"}