{"id":{"repo_id":"vu-aus","oai_identifier":"oai:eprints.vu.edu.au:21719"},"canonical_url":"https://search.dev.ndltd.org/etd/vu-aus/oai:eprints.vu.edu.au:21719","repository":{"repo_id":"vu-aus","name":"Victoria University (Australia)","base_url":"https://vuir.vu.edu.au/cgi/oai2"},"display":{"title":"Acceleration and fatigue in soccer","abstract":"This thesis investigated acceleration in soccer and the ability to improve acceleration capacity using supplementation and a training intervention both separately and in combination. Study one determined the validity and reliability of 5 and 10 Hz global positioning systems (GPS) for measuring instantaneous speed during the acceleration, deceleration and constant speed phase of straight-line running. The criterion measure used to assess GPS validity was instantaneous speed recorded using a tripod-mounted laser. Ten Hz GPS devices were 2-3 times more accurate than 5 Hz when compared to a criterion value for instantaneous speed during tasks completed at a range of speeds (coefficient of variation; 3.1 - 11.3%). Similarly, 10 Hz GPS were up to 6-fold more reliable for measuring instantaneous speed than 5 Hz units (coefficient of variation; 1.9 - 6%). Newer GPS may provide an acceptable tool for the measurement of constant speed, acceleration and deceleration during straight-line running and have sufficient sensitivity for detecting changes in performance in team sport. However, researchers must account for the inherent match-to-match variation reported using these devices.","abstract_html":"This thesis investigated acceleration in soccer and the ability to improve acceleration capacity using supplementation and a training intervention both separately and in combination. Study one determined the validity and reliability of 5 and 10 Hz global positioning systems (GPS) for measuring instantaneous speed during the acceleration, deceleration and constant speed phase of straight-line running. The criterion measure used to assess GPS validity was instantaneous speed recorded using a tripod-mounted laser. Ten Hz GPS devices were 2-3 times more accurate than 5 Hz when compared to a criterion value for instantaneous speed during tasks completed at a range of speeds (coefficient of variation; 3.1 - 11.3%). Similarly, 10 Hz GPS were up to 6-fold more reliable for measuring instantaneous speed than 5 Hz units (coefficient of variation; 1.9 - 6%). Newer GPS may provide an acceptable tool for the measurement of constant speed, acceleration and deceleration during straight-line running and have sufficient sensitivity for detecting changes in performance in team sport. However, researchers must account for the inherent match-to-match variation reported using these devices.","abstract_has_math":false,"creators":["Varley, Matthew C"],"institution":"Victoria University","degree_name":"phd","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-07-24T06:33:31Z","subjects":["1106 Human Movement and Sports Science","Institute of Sport, Exercise and Active Living (ISEAL)"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Varley, Matthew C"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Sport and Exercise Science; Institute of Sport, Exercise and Active Living"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Victoria University"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://vuir.vu.edu.au/21719/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["phd"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["1106 Human Movement and Sports Science","Institute of Sport, Exercise and Active Living (ISEAL)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://vuir.vu.edu.au/21719/1/Matthew_C_Varley.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis investigated acceleration in soccer and the ability to improve acceleration capacity using supplementation and a training intervention both separately and in combination. Study one determined the validity and reliability of 5 and 10 Hz global positioning systems (GPS) for measuring instantaneous speed during the acceleration, deceleration and constant speed phase of straight-line running. The criterion measure used to assess GPS validity was instantaneous speed recorded using a tripod-mounted laser. Ten Hz GPS devices were 2-3 times more accurate than 5 Hz when compared to a criterion value for instantaneous speed during tasks completed at a range of speeds (coefficient of variation; 3.1 - 11.3%). Similarly, 10 Hz GPS were up to 6-fold more reliable for measuring instantaneous speed than 5 Hz units (coefficient of variation; 1.9 - 6%). Newer GPS may provide an acceptable tool for the measurement of constant speed, acceleration and deceleration during straight-line running and have sufficient sensitivity for detecting changes in performance in team sport. However, researchers must account for the inherent match-to-match variation reported using these devices."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dc:title","label":"Title","values":["Acceleration and fatigue in soccer"]}]}],"canonical_facts":{"dc:creator":["Varley, Matthew C"],"dc:date":["2013"],"dc:date.issued":["2013"],"dc:description.abstract":["This thesis investigated acceleration in soccer and the ability to improve acceleration capacity using supplementation and a training intervention both separately and in combination. Study one determined the validity and reliability of 5 and 10 Hz global positioning systems (GPS) for measuring instantaneous speed during the acceleration, deceleration and constant speed phase of straight-line running. The criterion measure used to assess GPS validity was instantaneous speed recorded using a tripod-mounted laser. Ten Hz GPS devices were 2-3 times more accurate than 5 Hz when compared to a criterion value for instantaneous speed during tasks completed at a range of speeds (coefficient of variation; 3.1 - 11.3%). Similarly, 10 Hz GPS were up to 6-fold more reliable for measuring instantaneous speed than 5 Hz units (coefficient of variation; 1.9 - 6%). Newer GPS may provide an acceptable tool for the measurement of constant speed, acceleration and deceleration during straight-line running and have sufficient sensitivity for detecting changes in performance in team sport. However, researchers must account for the inherent match-to-match variation reported using these devices."],"dc:format":["text"],"dc:identifier.uri":["https://vuir.vu.edu.au/21719/1/Matthew_C_Varley.pdf"],"dc:language":["en"],"dc:publisher.department":["College of Sport and Exercise Science; Institute of Sport, Exercise and Active Living"],"dc:publisher.institution":["Victoria University"],"dc:relation.isreferencedby":["https://vuir.vu.edu.au/21719/"],"dc:subject":["1106 Human Movement and Sports Science","Institute of Sport, Exercise and Active Living (ISEAL)"],"dc:title":["Acceleration and fatigue in soccer"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["phd"]},"updated_at":"2026-07-24T06:33:31Z"}