Back to results

Virginia Tech

Spatially Resolved Equivalence Ratio Measurements Using Tomographic Reconstruction of OH*/CH* Chemiluminescence

Abstract

dc:description.abstract

Thermoacoustic instabilities in gas turbine operation arise due to unsteady fluctuations in heat release coupled with acoustic oscillations, often caused by varying equivalence ratio perturbations within the flame field. These instabilities can cause irreparable damage to critical turbine components, requiring an understanding of the spatial/temporal variations in equivalence ratio values to predict flame response. The technique of computed tomography for flame chemiluminescence emissions allows for 3D spatially resolved flame measurements to be acquired using a series of integral projections (camera images). High resolution tomography reconstructions require a selection of projection angles around the flame, while captured chemiluminescence of radical species intensity fields can be used to determine local fuel-air ratios. In this work, a tomographic reconstruction algorithm program was developed and utilized to reconstruct the intensity fields of CH* and OH*, and these reconstructions were used to quantify local equivalence ratios in an acoustically forced flame. A known phantom function was used to verify and validate the tomography algorithm, while convergence was determined by subsequent monitoring of selected iterative criteria. A documented method of camera calibration was also reproduced and presented here, with suggestions provided for future calibration improvement. Results are shown to highlight fluctuating equivalence ratio trends while illustrating the effectiveness of the developed tomography technique, providing a firm foundation for future study regarding heat release phenomena.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Giroux, Thomas Joseph III
Chair dc:contributor.committeechair
  • Meadows, Joseph
Committee members dc:contributor.committeemember
  • Ng, Wing Fai
  • Lowe, K. Todd

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:27035
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/99444

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Giroux, Thomas Joseph III. Spatially Resolved Equivalence Ratio Measurements Using Tomographic Reconstruction of OH*/CH* Chemiluminescence. masters thesis, Virginia Tech, 2020. http://hdl.handle.net/10919/99444