Back to results

Virginia Tech

Ultra-wideband Radar Detection of Breathing Rate: A Comparative Evaluation

Abstract

dc:description.abstract

This work explores the use of a commodity ultra-wideband (UWB) radar based device to detect breathing rate for health monitoring applications. Health monitoring devices observe physiological signals to detect medical conditions. We focus on capturing the small mechanical movements caused by breathing. This is traditionally done via a strain gauge worn around the chest or stomach, but these systems limit user movement. Contactless systems provide a unique design that allows free user movement by eliminating all direct contact with the user. Additionally, these systems have the potential to support full health monitoring in a Smart Built Environment (SBE). In this work, a comparative evaluation is performed on a commodity UWB radar based device, the Walabot, to determine the accuracy and possible health monitoring applications. Based on results from a systematic review, six research challenges were identified: (1) high cost, functional limitations based on the user's (2) location, (3) orientation, and (4) movement, (5) dependency on system hardware placement, and (6) vulnerabilities in signal processing methods. A comparative evaluation was designed to test the Walabot against a medical grade wearable system in the context of these research challenges. The data was processed using two breathing rate derivation techniques: Fast Fourier Transformation (FFT) and Peak Detection. Results suggest great potential for the Walabot coupled with the FFT technique. However, the system requires further testing to address all of the research challenges. Overall, this work provides important steps toward using the Walabot in health monitoring applications.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Computer Engineering
Department dc:contributor.department
Electrical and Computer Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Buckingham, Nicole A.
Chairs dc:contributor.committeechair
  • Martin, Thomas L.
  • Gracanin, Denis
Committee member dc:contributor.committeemember
  • Butt, Ali R.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:25933
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/98597

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Buckingham, Nicole A.. Ultra-wideband Radar Detection of Breathing Rate: A Comparative Evaluation. masters thesis, Virginia Tech, 2020. http://hdl.handle.net/10919/98597