Back to results

Virginia Tech

Mount Interference and Flow Angle Impacts on Unshielded Total Temperature Probes

Abstract

dc:description.abstract

Accurately measuring the total temperature of a high-speed fluid flow is a challenging task that is required in many research areas and industry applications. The difficulty in total temperature measurement generally stems from attempting to minimize measurement error or accurately predict error so it can be accounted for. Conduction error and aerodynamic error are two very common sources of error in total temperature probe measurements. Numerous studies have been performed in prior literature to account for simple cases of both errors. However, the impacts of a mounting strut and freestream flow angle on conduction error and aerodynamic error have not been previously modeled. Both of these effects are very common in gas-turbine applications of total temperature probes. Therefore, a fundamental study was performed to analyze the impact of mount interference and freestream flow angle on a probe's conduction error and aerodynamic error. An experimental study of aerodynamic error was performed using strut-mounted thermocouples in a high-speed jet at Mach numbers ranging from 0.25-0.72. This study showed that a strut stagnation point can provide aerodynamic error reductions and insensitivity to approach Mach number. An off-angle experimental study of conduction error was also performed using strut-mounted thermocouples at pitch angles ranging from -30° to 30°. High-fidelity Computational Fluid Dynamics (CFD) simulations with Conjugate Heat Transfer (CHT) were performed in conjunction with the experiments to provide key heat transfer information and flow visualizations. It was identified that unshielded total temperature probes have reduced conduction error at off-angles, but are sensitive to changes in the freestream flow angle. A low-order method was developed to account for mount interference and flow angle effects. The developed low order method utilizes a local Mach number for aerodynamic error predictions and a local Reynolds number for conduction error predictions. This developed low-order method was validated against experiment and 3D, CFD results, and was shown to accurately capture flow angle trends, mount interference effects, and the impacts of varying probe geometry.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Aerospace Engineering
Department dc:contributor.department
Aerospace and Ocean Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Quickel, Reuben Alexander
Chairs dc:contributor.committeechair
  • Schetz, Joseph A.
  • Lowe, K. Todd
Committee member dc:contributor.committeemember
  • O'Brien, Walter F. Jr.

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:20237
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/89952

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Quickel, Reuben Alexander. Mount Interference and Flow Angle Impacts on Unshielded Total Temperature Probes. masters thesis, Virginia Tech, 2019. http://hdl.handle.net/10919/89952