Back to results

Virginia Tech

Hypothermic Machine Perfusion of Composite Tissues

Abstract

dc:description.abstract

Organ perfusion systems have successfully been applied to solid organ preservation and subsequent transplantation. However, their use in limb preservation for Vascularized Composite Tissue Allotransplantation (VCA) has yet to be thoroughly investigated. This thesis explores the potential for hypothermic machine perfusion in prolonging limb graft viability in a swine forelimb amputation model. The experiment was designed with the right and left forelimbs from the same pig randomly assigned to the treatment and control groups. Eighteen (18) limbs were procured from a local abattoir, vessels cannulated, and an initial flush of a modified phosphate buffered saline (PBS) solution was performed. Half of those limbs, assigned to the treatment group, were then preserved with continuous hypothermic machine perfusion for 12 hours. The perfusate was a PBS solution supplemented with 5% w/v dextrose. The remaining nine limbs, assigned to the control group, were placed into a plastic bag and kept at room temperature (ca. 20oC) for the entire duration of the experiment. Methylene blue was used to verify perfusion throughout limbs. Histopathological analysis revealed the presence of significantly greater deterioration of the perfused limbs compared to control. I concluded that PBS solution is not suitable for extended limb preservation. Inadequate perfusate volume and lack of solution replenishment resulted in metabolic waste build up, accelerating total organ damage. Continued research is needed in order to develop clinically relevant hypothermic machine perfusion devices capable of prolonged limb preservation.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Troutman Mr., Eric Christopher
Chair dc:contributor.committeechair
  • Robertson, John L.
Committee members dc:contributor.committeemember
  • Paul, Mark R.
  • Diller, Thomas E.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:13693
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/81272

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Troutman Mr., Eric Christopher. Hypothermic Machine Perfusion of Composite Tissues. masters thesis, Virginia Tech, 2017. http://hdl.handle.net/10919/81272