Back to results

Virginia Polytechnic Institute and State University

Reproducibility of a continuous-wave Doppler ultrasound system for assessment of ascending aortic blood flow responses during graded exercise testing with healthy individuals

Abstract

dc:description.abstract

Continuous-wave (CW) Doppler recordings of ascending aortic maximal blood flow acceleration (PkA), maximal velocity (PkV) and systolic velocity integral (SVI) were taken at each stage of a graded exercise treadmill test on two separate days with 30 physically active adult males. Signals were measured (Quinton Exerdop) for all cardiac cycles in the 3rd minute of each stage using a hand-held probe positioned at the suprasternal notch. A dedicated microcomputer, programmed to select "valid" beats on the basis of value consistency in the sample set, determined the acceptability of signals. No significant differences were found between the three trial means within each stage on either day for PkA, PkV or SVI. Significant (p <.01) intraclass reliability estimates ranged from r = 0.89 to 0.97 (Pk.A), r = 0.90 to 0.98 (PkV) and r = 0.85 to 0.95 (SVI) . Coefficients of variation were calculated at each stage to estimate the relative consistency of each measure. A gradual reduction of the coefficient of variation was observed for each blood flow measure between stages one and four. The test-retest (between days) reliability coefficients for PkA, PkV and SVI for stages one to four ranged between r = 0.51 to 0.78 (P <.004), but correlations for the pre-exercise baseline and stages five and six were lower. These results indicate that (1) PkA, PkV and SVI demonstrate greater measurement stability within each stage of a graded exercise test than is the case between separate days of measurement at the same stage; and (2) there is modest day-to-day response stability for clinical testing with the Doppler parameter of PkV. Reliability/stability was best in exercise stages which encompass the speed and grade range of 45.0 m•min⁻¹/10%. - 111.7 m•min⁻¹/14%, i.e., those in which all subjects can walk.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Health and Physical Education
Department dc:contributor.department
Health and Physical Education
Grantor dc:publisher
Virginia Polytechnic Institute and State University
Year dc:date.issued
1987

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wetherill, Lindsay D.

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10919/80102
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/80102

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Wetherill, Lindsay D.. Reproducibility of a continuous-wave Doppler ultrasound system for assessment of ascending aortic blood flow responses during graded exercise testing with healthy individuals. masters thesis, Virginia Polytechnic Institute and State University, 1987. http://hdl.handle.net/10919/80102