Back to results

Virginia Tech

Optical Measurements of High-Viscosity Materials Using Variations of Laser Intensity Incident on a Semi-Rigid Vessel for use in Additive Manufacturing

Abstract

dc:description.abstract

Additive manufacturing is a growing field dominated by printing processes that soften and re-solidify material, depositing this material layer by layer to form the printed shape. Increasingly, researchers are pursuing new materials to enable fabrication of a wider variety of associated capabilities. This includes fabrication with high-viscosity materials of many new classes of material compositions, such as doping for magnetic or electrically conducting polymers. These additives complicate the materials deposition process by requiring complex, non-linear calibration to synchronize these new candidate materials with the additive manufacturing software and hardware. In essence, additive manufacturing is highly dependent on identifying the delicate balance between materials properties, hardware, and software-which is currently realized via a time-consuming and costly iterative calibration process. This thesis is concerned with reducing this cost of calibration, in particular by providing a time-based metric based on material viscosity for material retraction at the conclusion of each extrusion. It presents a novel non-contact method of determining the material retraction rate (during reversal of extrusion), by measuring the variation in laser intensity resulting from the deformation of the material reservoir due to change in material pressure. Commercially available laser measurement systems cost more than $20,000 and are limited to 1 μm at a 300 ms (3 Hz) sampling rate. The experimental setup presented in this thesis costs less than $100 and is capable of taking measurements of 1 - 2 μm at a 0.535 ms (1870 Hz) sampling rate. For comparison, the stepper motor driving the material extruder operates at 0.667 ms (1500 Hz). Using this experimental setup, an inverse correlation is shown to exist between the viscosity of a material and the rate at which the material is retracted. Using this correlation and a simplified material analysis process, one can approximate the retraction time necessary to calibrate new materials, thereby significantly improving initial estimated calibration settings, and thus reducing the number of calibration iterations required to ready a new material for additive manufacturing. In addition, the insight provided into the material response can also be used as the basis for future research into minimizing the calibration process.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pote, Timothy Ryan
Chair dc:contributor.committeechair
  • Bøhn, Jan Helge
Committee members dc:contributor.committeemember
  • Williams, Christopher B.
  • Lu, Guo-Quan

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Dc Identifier Other
etd-05162017-115826
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/79595

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Pote, Timothy Ryan. Optical Measurements of High-Viscosity Materials Using Variations of Laser Intensity Incident on a Semi-Rigid Vessel for use in Additive Manufacturing. masters thesis, Virginia Tech, 2016. http://hdl.handle.net/10919/79595